Recent content by ljcni99

  1. L

    Concrete base 6m x 4m on sloping ground..

    Hi, looking some help or ideas for the concrete base I am planing to lay. The base is for a steel shed/workshop measuring 6m x 4m. The problem is that the site I intend to build it on is at a slope. It slopes by approx 2ft from front to back. I am thinking I will need to build a retaining...
  2. L

    Concrete steel garage base!?

    Hi, I am. Planning to put up a steel garage 6m x 4m. First I need to put down a concrete base for said garage. The site for it is at a slight slope. Slopes by around 1.5 ft from front to back. To level this for the concrete base i had though of just building a block retaining wall the full...
  3. L

    New Oven and hob???

    http://www.beko.co.uk/manuals/ODF22300_21300.pdf page 5 of this manual. This is the oven bought. thanks alot for the help :)
  4. L

    New Oven and hob???

    the manual says fuse protection minimum 25A fuse for the oven and grill. would the cable go CU---> cooker switch----> hob ---->Oven ??
  5. L

    New Oven and hob???

    Im putitng in a new kitchen as i have just bought a house. The old kitch had standalone oven and hob. 45A fuse, 6mm cable to cooker switch, 6mm cable to cooker. Our news kitchen has a built in eye level double oven and built in hob. Grill = 2.1kW Oven = 1.8 kW Hob = 7.2 kW Will...
  6. L

    extending ring final conduit in wall...

    yea its in a safe zone. Use both at work really....plasyic and steel. Both easy to work with. I not is a chaser..... typed that in first post.... just a wee mistake lol. Thanks for all you comments fellas cheers
  7. L

    changing consumer unit......???

    basically he want extra capacity to: 1) Get power to a shed 2) New en-suit 3) Aging ( would like MCB's instead of fuses) I was thinks on a Split RCD 80A 30 mA I actually was originally asking what type (make of CU) do you reccommend. Sorry for the confusion but do appreciate all...
  8. L

    extending ring final conduit in wall...

    well i am not getting paid however i am one of these people who always wants to know how to do the job right. I am an electrical maintenance engineer and comfident in wiring up comercial thing. But thats all stell conduit screwed to the wall just wanting to know whats the proper way to do it...
  9. L

    extending ring final conduit in wall...

    and btw its my dads house. No payment
  10. L

    extending ring final conduit in wall...

    its pretty simple. Im am simply going to take a spur of the ring main. I have read a few of your replys to other peoples questions and they do not seem to be any help at all..... if you have nothing helpfull to say then i suggest you do not reply to my posts. Thanks SAo for everyone else your...
  11. L

    extending ring final conduit in wall...

    ok so i want to extend the ring final. The new socket will be about 2 metres away form the one i will extend it off. I am going to hire a wall chaser to track the wall to put the conduit in. Is it ok to use PVC conduit as his CU is just fuses or does it have to be steel conduit?
  12. L

    changing consumer unit......???

    hi. My dads CU needs could do with being changed. All fuses with no spares for extra circuit or extensions. What CU do you recommend? Split loads RCD protected? Thanks
  13. L

    they're 'avin a laugh...

    oh and i work 7-3 one week and 3-11 next. With friday being a half day. Average 38 Hour week
  14. L

    they're 'avin a laugh...

    thats poor pay. Im just out of my time as electrical maintenance technician.... and i get £380 per week aand am on bottom grade money atm
  15. L

    High socket for tv

    is the problem the shower circuit? I no its a 40 Amp fuse in the CU thats why i thought it would be ok to take a 13A spur from the shower