Hi All
Can anybody advise me at what point is emergency lighting legally required for a multiple occupancy property example: Students sharing a 3 storey house. Is it based on number of floors, number of occupants etc ?
Many thanks
Mark
Hi Paul
Sounds like you are on the right track. 20amp double pole is fine. I am assuming that each storage heater circuit is protected by 15 or 16 amp fuse at consumer unit. You will need 1.5mm 3 Core Buytl Flex which is rated at 16amp.
I know we all love pictures so heres one from today's job.
Could have been nasty while putting the hoover away !! No nut and bolt holding it closed, just flapping about open.
Just done PIR and found this. Am I right that this fusing of the neautral is no longer safe practice ? Must be...
Yeah. Found quite a few faults on this one ( some rough diy) which I couldn't walk away from without sorting.
Now I've calmed down I guess a Code 4 is fair comment.
Hi all
PIR today. TT setup. 100mA RCD , Socket outlets on RCBO's.
RCD not time delayed. What code would you give this. Was thinking code 2.
Cheers for any feedback
Yes John D. Thats the kind of setup I have seen. However as Securespark and yourself have pointed out , am I wrongly informed that descrimination is not an issue ?
Cheeers guys. Wanna clear this one in my head !!