Recent content by marcusone

  1. M

    Emergency lighting in Multiple Occupancy Properties

    Hi All Can anybody advise me at what point is emergency lighting legally required for a multiple occupancy property example: Students sharing a 3 storey house. Is it based on number of floors, number of occupants etc ? Many thanks Mark
  2. M

    Combined bathroom ceiling light and radiant heater.

    Are these monstrous things still available ? Have a customer who seems to think so and wants one replaced. Cheers Mark
  3. M

    Earthing Back Box

    Yes. You also have to earth the metal back box.
  4. M

    Found this open in a cupboard. Ouch !!

    I've secured the the service head closed and will be on the phone in the morning. Thanks guys .
  5. M

    connecting replacement storage heaters

    Hi Paul Sounds like you are on the right track. 20amp double pole is fine. I am assuming that each storage heater circuit is protected by 15 or 16 amp fuse at consumer unit. You will need 1.5mm 3 Core Buytl Flex which is rated at 16amp.
  6. M

    Found this open in a cupboard. Ouch !!

    I know we all love pictures so heres one from today's job. Could have been nasty while putting the hoover away !! No nut and bolt holding it closed, just flapping about open. Just done PIR and found this. Am I right that this fusing of the neautral is no longer safe practice ? Must be...
  7. M

    Max disconnection time for electric shower

    Cheers. Just having a blank moment. Mark
  8. M

    Max disconnection time for electric shower

    Sorry guys, pretty sure it's 5 sec but damned if I'm going out to van for book in this weather. Can anyone remind me. Thanks Mark
  9. M

    PIR RCD query

    Yeah. Found quite a few faults on this one ( some rough diy) which I couldn't walk away from without sorting. Now I've calmed down I guess a Code 4 is fair comment.
  10. M

    PIR RCD query

    Hi all PIR today. TT setup. 100mA RCD , Socket outlets on RCBO's. RCD not time delayed. What code would you give this. Was thinking code 2. Cheers for any feedback
  11. M

    Electrical Software

    I use a program called Easycert. Great bit of software and proffesional results. www.tysoft.co.uk
  12. M

    Incoming TT supply

    Our local supplier charges about £60.00. Definately worth going for if you can get it.
  13. M

    Dual RCD Consumer Units

    Happy now. Looks like there has only ever been one way to doi it right. Sticking with the Type S set up. Thanks everyone. Marcus
  14. M

    Dual RCD Consumer Units

    So this basically takes the RCD's out of series. Hence no descrimination. (or not ??? ) :?
  15. M

    Dual RCD Consumer Units

    Yes John D. Thats the kind of setup I have seen. However as Securespark and yourself have pointed out , am I wrongly informed that descrimination is not an issue ? Cheeers guys. Wanna clear this one in my head !!
Back
Top