We have just laid 30 sqm of slate tiles and they have white marks/stains on the edges. All the marks are on what was the bottoms when they were stacked on the pallet. I assumed they were just water marks from standing outside and would just wipe off. We have tried a stiff nylon brush and a...
We are renovating a house and need to move the head of the stairs back to allow for a new staircase with a left turn at the top. I originally thought the header ran just the width of the staircase but after lifting the floor I found it runs the whole way to the outside wall.
In the picture. I...
We have just inherited a property that is in need of total renovation and I have a question about a roofing problem. The chimney flashing has failed and allowed water into the roof space. This has gone on for an extended period and the purlin has rotted out where it meets the chimney breast.
I...
We have an oil delivery booked for Friday but we ran out earlier today. We topped the tank with 150L from containers, bled the first boiler from the Allen key until the oil ran free and it fired up fine.
Did the same on the second one but that had an E9 over temp error. We reset the thermostat...
Thank you. I just got back from the customers and the CH valve is gone. I observed the HW valve moving the arm but the CH one was dead. I moved the arm by hand and it turned off the boiler but there was zero resistance so the motor is clearly shot.
Last question. It is a Drayton ZA5 valve...
Internal wall hung and non system going on the pictures on the grant spares site. The control panel is a MPCBS108
I thought the frost stats wired into the wiring centre but if it is somewhere else then I will check it.
Thank you.
I am an Electrician and I have just been called to a Grant Vortex Eco that will not turn off.
All the external controls are correct. The 2 control wires from the wiring centre to the boiler switch the 230v on and off when you request HW or CH. However, with both of them off the boiler still...
Thanks for the replies. I didn't realise these water to water heat exchangers were so efficient. Well I will wire the pump in about a week and we will see how it runs. Thanks again.
I am an Electrician and I have been asked to wire up the electrics for a friend's Biomass boiler that is located in an outbuilding. I am deeply concerned about the planned heat exchanger in the home and I have a question.
The plan is to install a small heat exchanger (shoe box size) inside the...
I wish to cut out some blockwork for a doorway on the 1st floor. The blockwork has nothing directly above it but is close to a steel that supports the roof. A picture says a thousand words so how close to the edge of the steel can I cut the red line?
Just to be clear, I will be removing the...
Check it where mate? Before the pump it is just gravity and the tank is only a few inches higher than the pump so it is next to nowt and at the outlet in is actually nowt. Sorry if I am missing something...