  1. Meza

    DIY Smart Wifi/RF Alarm Project

    Or have you thought about using something like SmartThings? You could do it with that.
  2. Meza

    DIY Smart Wifi/RF Alarm Project

    I'd say all you really need is another sonoff with relay/volt free/dry contacts and a 12v power supply. No need for an alarm panel. Wire the sonoff to switch the bell trigger. Then use the sonoff app on your phone to turn the siren on or off.
  3. Meza

    Recommend a heat/smoke alarm with built in sounder for use with DSC PowerSeries panel

    I'm upgrading an old wired alarm system. It's time to do the smokes. The old system had traditional looking smoke detector wired to the panel. When triggered the panel would alarm and so would the smoke detector via a built in sounder. I've bought a selection of four-wire Texecom Exodus sensors...
  4. Meza

    How to wire UK Texecom siren to DSC PowerSeries panel?

    Found this handy wiring diagram tucked at the back of the panel installer manual. Maybe helps someone else in the future.
  5. Meza

    How to wire UK Texecom siren to DSC PowerSeries panel?

    Sorry I should have clarified - the group 4 unit was running on a different old panel, which has now been replaced with the new DSC panel.
  6. Meza

    How to wire UK Texecom siren to DSC PowerSeries panel?

    I found this table on a useful website (https://www.diy-alarms.co.uk/pscatalog/modules/blocknews/item.php?item_id=7): SIREN DSC PANEL Neg Hold Off AUX - Pos Hold Off BELL + Bell Trigger BELL - Strobe Trigger PGM1 Tamper Return ZONE...
  7. Meza

    How to wire UK Texecom siren to DSC PowerSeries panel?

    Hi, I'm trying to set up a Texecom Odysey X3 siren on a DSC PowerSeries PC1832 panel. I can't work out the wiring from the panel to the siren. The DSC has just two bell outputs: Bell + Bell - The Texcom Odysey X3 has +12v Bell Tmp 0v Strb Please can someone explain how I should connect these...
  8. Meza

    Unable to disarm DSC PC1832 via delay zone, system goes into alarm

    Didn't think of that. Likely to cause an issue do you think? Is there an operating temp range for panels? It certainly is the most secure location to avoid tampering.
  9. Meza

    Unable to disarm DSC PC1832 via delay zone, system goes into alarm

    Yeah, my keypads are BG branded. Wardrobe install - more secure/hidden location? I'm moving mine from downstairs w/c up into the loft.
  10. Meza

    Unable to disarm DSC PC1832 via delay zone, system goes into alarm

    Thanks for the suggestion. I stumbled across the solution in another engineer's setting: preventing entry of user codes during entry delay - bizarre! Turned that one off and we're in business now.
  11. Meza

    Unable to disarm DSC PC1832 via delay zone, system goes into alarm

    Hi, I am installing a DSC PowerSeries PC1832 panel and having trouble disarming. With the alarm set, when I enter via a delay zone I am unable to disarm the system with the user code. After the delay the alarm enters the alarm state, at which point I am able to stop the alarm with the user...