Recent content by monk2601

  1. M

    pipe stat problem

    i was wondering does anyone know which way is best to wire a pipe stat to a stanley solid fuel stove,stanley recommend that you fit it on the flow.here,s my problem,i have the stat on the flow and its wired so as when the pipe reaches 60 degrees the pump comes on,however whenever the pipe cools...
  2. M

    how to wire a high and low limit stat to solid fuel stove

    hi just wondering does anyone know how to wire a high limit and a low limit stat to a solid fuel boiler
  3. M

    injector tee and bad flow to cylinder

    its a stanley lismore,no i made the injector using a 28 mm to 15 mm solder reducer pushed into a 28mm tee,i looked them up online and it was recommended to make one up like that because they were hard to come by and fairly expensive,well ill go and get a proper injector tee and try that to see...
  4. M

    injector tee and bad flow to cylinder

    i have 28mm pipes coming from my stove and connecting to my cylinder, i tee,d off these pipes in 22mm to connect to my rads. i have the flow rising from the stove to the cylinder and the return is falling back to the stove,the gravity circuit is working perfectly when the pump is off its only...
  5. M

    injector tee and bad flow to cylinder

    i have 2 direct flow and returns coming from my stove [1 flow and 1 return] to the hot press by gravity circuit.i took a tee off the flow in the hot press and connected to my rads.where my gravity return comes out of the cylinder this is where the injector tee is with my rad return connected to...
  6. M

    injector tee and bad flow to cylinder

    i have recently installed a stanley solid fuel stove, i have the flow and return connected to the cylinder by a gravity circuit and the rads are pumped,however whenever the pump comes on the the flow to the cylinder does not heat,i fitted an injector tee as specified by the manufacturers...
  7. M

    system link

    i was wondering what is the best way to connect a heating system to a solid fuel stove and oil boiler, i was thinking by using a system link any tips would be appreciated
  8. M

    riello burner lockout

    im not sure its an outdoor boiler so he does be inside whenever it happens and only knows it locks out when the rads dont heat up, ill try find out and let you know thanks much appreciated
  9. M

    riello burner lockout

    hi,my friends riello burner will go to lock out after about 2 hours, it works perfectly up to this point, water and rads all heat up and the boiler does fire up again when the stat reaches temp however for some strange reason the odd time it goes to lock out after working perfectly for about 2...