Recent content by ms2004

  1. M

    Thermostat Change

    Evening Just wanted confirmation about changing a thermostat. Existing is Danfoss dial type. 3 wires. N = grey, L = brown, Switched live = Black (taped brown) New is Honeywell DT90e. Only 2 wires required. Terminal A would be switched live? Terminal B would be live? Neutral and earth will...
  2. M

    Sister joists with a single one?

    Hi, Just wanted some clarification on this. We have a small hallway that adjoins a porch. There are 3 no. joists from the hallway resting on a stone foundation. All 3 joists have rotted at the ends. Either side of joists 1 and 3 are rooms with concrete floors. The concrete has been installed up...
  3. M

    Cap pipes...

    ok thanks, thats helpful. Plumber will be coming a week or so later so nothing long term. Just need to remove the pipework so the builder can do his bit. The pipework is currently lower than the concrete floor will be.
  4. M

    Cap pipes...

    Evening I need to remove a radiator and the corresponding section of pipework from my CH system to enable my builder to put in a concrete floor. I can access the pipework under the floor. My plan is to cut the pipes and put a pushfit stop end on until the plumber comes to put in the new...
  5. M

    MCB labels

    Quick question.... A friend of mine (qualified sparky) did me a favour and installed a new CU. He went back offshore and is now remaining offshore due to the virus. He was meant to come back and label the MCBs but didnt. As Im now getting bored at home I was going to do this myself. I assume...
  6. M

    NO/NC switch

    Yes please, Thanks very much, voltage is 24V.
  7. M

    NO/NC switch

    Yes, you're right, thats how it works. I assume there is something in a traffic light that keeps it on until the traffic light goes red. Doesnt matter, we can just wire it up to a plug and he can use it like a normal light. Thanks for your help.
  8. M

    NO/NC switch

    Evening, My friend has aquired a pedestrian crossing "Wait" push button unit. He wants to put it in his garden, but I dont know enough about wiring it and he knows even less. The push button simply connects to a NO/NC microswitch. He wants to be able to hit the button and turn the light on and...
  9. M

    Beacon keeps flashing...

    Thanks for the replies. There is no battery in the beacon unit and as there was moisture present, I assumed the beacon is faulty rather than the control panel. I will buy another beacon.
  10. M

    Beacon keeps flashing...

    Looking for some advice. Have a Klargester treatment plant that has a control panel monitoring its functions/faults. When a fault is detected, the system flashes a beacon outside. For the past 6 months or so, the beacon has been flashing, but there is no fault. The beacon doesnt flash as it...
  11. M

    Searching for manual

    Thanks I’ll try the Spit site. I would only use for DIY if anything but thought it might be a handy thing to have. It came with a box of shots and some nails. Wasn’t expensive so it will probably gather dust a lot of the time.
  12. M

    Searching for manual

    Thanks photo below, they do look similar
  13. M

    Searching for manual

    Im hoping someone can help me. I bought a job lot of tools second hand. One of them is a powder actuated nail gun. Im trying to find a manual for it, but Ive trawled the internet and come up with nothing. Its a Rawl PAT90A nail gun, looks to be originally from France. Anybody know of a site...
  14. M

    Pipes vibrating

    No, haven’t had a new boiler. They were clipped to the concrete but must have been rubbing on something. Pin hole leak. Mind you, it must have been there for at least 30 years without a problem.