Recent content by Murdhie

  1. M

    Vokera 24 pressure switch bypass anomaly.

    It's through my bank account. Insurance up to £250 for emergency boiler cover. The Bank contact their approved heating engineers and then the heating engineers contact me. Point taken on the bypass.
  2. M

    Vokera 24 pressure switch bypass anomaly.

    He's put it through as a main board issue so we'll see what happens when it's fitted on Wednesday. The lad that initially came out left the bypass and made no mention of it not being good practice. To be fair I would have let him do it anyway as I felt it was safe as a very temporary fix. The...
  3. M

    Vokera 24 pressure switch bypass anomaly.

    Ian, sorry,yes ignition pcb. I think he was saying that the fan gets it's power from the main board and as the fan is only working intermittently then the main board must be at fault. When the low water contents switch was bypassed the boiler worked flawlessly until the switch was replaced...
  4. M

    Vokera 24 pressure switch bypass anomaly.

    Intermittent fault. Sometimes power not being sent to the fan so the boiler won't fire up. Diagnosis is a fault with the main board. Many thanks to the guys that replied. Dan, If you read the whole thread that you referred to you'll find that I was perfectly civil until someone tried to get...
  5. M

    Vokera 24 pressure switch bypass anomaly.

    ianmcd thanks for that. Right now the guy thinks it's either the ignition switch or main board. He's off to see what he has in the van.
  6. M

    Vokera 24 pressure switch bypass anomaly.

    Sorry guys the gas fitter is here now. If anyone is still curious as to whats going I'll get back to this when he's done.
  7. M

    Vokera 24 pressure switch bypass anomaly.

    The image below is the new pressure switch.
  8. M

    Vokera 24 pressure switch bypass anomaly.

    Sorry, was emptying boiler cupboard. An air pressure switch. The image below is of the switch that was replaced.
  9. M

    Vokera 24 pressure switch bypass anomaly.

    The guy that fitted the part expressed some doubt about the part which is why I did an Internet search on it.
  10. M

    Vokera 24 pressure switch bypass anomaly.

    Hi, thanks for you reply. It's a vokera compact 24.
  11. M

    Vokera 24 pressure switch bypass anomaly.

    Rude comments? No offence was meant in any way. Which comments were rude?
  12. M

    Vokera 24 pressure switch bypass anomaly.

    Hi Guys, I'm not a gas fitter. Not trying to repair this myself. The guy is coming out again today. I just like to be informed and it's starting to annoy me. My Vokera stopped firing up. 2 Guys came out three times. First 2 times a young lad then a more experienced guy. Diagnosed as...
  13. M

    Vokera Red Light

    Does DP stand for double penetration? I hope you got a reach around.
  14. M

    Vokera Red Light

    To Jacobball The lackey comment was for your unhelpful friend not you. I am a fine furniture maker to trade and do not think for a minute that fellow tradesmen are lackeys. I just don't have time for people who get in touch to tell me they don't want to help, know what I mean. If you don't...
  15. M

    Vokera Red Light

    Paying a lackey to do what I can do myself for a tenth of the price doesn't sound like common sense to me. You really need to chill out my small sacked friend :0)