I fitted a wireless PIR in my shed about 18 months ago and all was fine until a month ago I got a false alarm. I put it on a soak test for 14 days and all was well until last night when I was awoken at 02.30 AM.
I have now set the PIR to low sensitivity and 2 pulse hoping that will help.
My...
I have a drip coming from the bottom of the heat exchanger when the burner has been on for a while.
Will the heat exchanger have to be replaced or could it be a seal? And is it worth doing as it's an expensive part and and it's an old boiler?
Thanks Iain
Hi, I have a Galaxy 2-20 system and would like to connect my doorbell to it so it uses the chime function.
Is this possible?
If so would I need a push button with a N/C contact?
How would I connect and program it?
Thanks.
Yes Risco! I think you've nailed it guys. I think this looks like a direct replacement.
https://www.hunters-wholesalers.co.uk/risco-06097-shockguard-white-p-85332.html
This one woke me up at 4 AM this morning. lol. It wasn't working on the walk test until I put the sensitivity all the way up about a month ago, even then it was a bit temperamental. Also the led dosn't work.
I think Gardiner has gone out of business. Have they been taken over by Gardtec? I'm...
Could someone recommend a replacement shock sensor.
The one fitted is a "Gardiner shockguard" on a Honeywell G2-20 panel.
It is fitted on the same zone as a magnetic door contact, just a few inches away
I was thinking about a HoneyWell Viper GL, but I believe it requires 6 wires.
This worked for me to reset the alarm codes to default. I have a G2-20 panel, but I believe it works on the G2-44 also.
Remove all the covers from panels
pull fuse for mains.
Disconnect batteries.
Disconnect wire from Tamper (marked T on board)
Disconnect wires from zone 1 and link with a bit of...