Recent content by Samal

  1. S

    Conservatory roof conversion

    Mister Banks Thank you, I am with Kingston Upon Thames council, whoa re you with What documents you had to provide please
  2. S

    Conservatory roof conversion

    The conservatory and the side ground floor room were part if planing granted and complted in 2006, I want to convert the roof of the conservatory to a warm flat room with roof lentern. The front will change but will remain glass windows and doors, possibly trifold or sliding. Will add insulation...
  3. S

    Recommendation room thermostat which can be controlled using an app when away from home

    Hotwater will be off when away from home, so no need to control this.
  4. S

    Recommendation room thermostat which can be controlled using an app when away from home

    My aim is able to see what room temperature it is and set the required temperature when away from home. My setup is Greenstar 30CDI System boiler, separate hot (middle floor) & cold (loft) water tanks, gravity fed. Currently have Honeywell Home Thermostat DT200 = T6620B1008 (battery powered)...
  5. S

    Honeywell Galaxy 2-12 C012

    Thanks GalaxyGuy
  6. S

    Honeywell Galaxy 2-12 C012

    Hi Had the guy who installed it come round and do this He also gave me the Engineer Code, so now I have our user code and engineer code Will I ever need any other code ?
  7. S

    12v 7.0Ah Rechargeable SLA Battery PS-1270 Power Sonic

    Hi Just had my alarm (Honeywell Galaxy 2-12 C012) battery replaced with this one. What the quality like compared to say Yuasa mentioned on this forums? Thanks
  8. S

    Honeywell Galaxy 2-12 C012

    Thanks GalaxyGuy
  9. S

    Honeywell Galaxy 2-12 C012

    Hi All It's time to change the battery Reading all the posts I know what to buy and I think how to change My concern is that I don't know is if the panel has the tamper alarm connected or not. What happens if it is? Will my User Code silence the bell Am I able to change the battery using my...
  10. S

    Leaky Conservatory

    Crafty - thanks for a quick response First leak is in the corner, one side jointed to a brick wall and other to flat roof facia. The other to brick wall only. Where the joint is with brick wall, between the gutter and wall there is mastic with lead flashing over. My concern is that the...
  11. S

    Leaky Conservatory

    We had conservatory fitted last summer, leaks have appeared over two location where it butts to the wall, unfortunately for us the firm who fitted it have gone bust. The problem is there is no fall on the gutters and the two leaks. What's the beat way to resolve this, try and seal the...
  12. S

    22 mm to 38 mm connection

    Sorry Guys, I am after 22mm to 1.75 Inch Thank you
  13. S

    22 mm to 38 mm connection

    Guys please help, My 30CDI greenstar (Worcester) boiler has a 22mm condensate pipe, need to connect this to a bath room waste pipe which is 38mm (1.5 Inch). How do I go about this please :(
  14. S

    New Boiler

    The chosen boiler is Worcester Greenstar 35CDI Combi NG Boiler, would this be suitable for what we wish to do ?
Back
Top