Recent content by sh4tz

  1. S

    loft floor joist direction

    I also would like to know if this is a sound idea. Similarly, my semi detached has current 4x2 joists running from back to front with the joist span only being half the length of the house as they sit on a cental dividing brick wall. I want to do same as you and fix new elevated joists...
  2. S

    HELP Split under purlin. ..urgent attention required?

    Thanks guys this is reassuring. I'm replacing roman pan tile like for like so weight should be similar. I didn't realise a shake could result in the purlin splitting in half to this degree and deflecting so that it's face is no longer flush and uniform. It's amazing how wood retains so much...
  3. S

    HELP Split under purlin. ..urgent attention required?

    Was in the loft and noticed a long crack pretty much all the way along the under purlin to the front elevation of the property. It's a deep crack, about 2cm deep and about 8mm wide... see the attached photos how the roof structures down pressure weight has I beleive resulted in the purlin...
  4. Untitled

    Untitled

  5. Untitled

    Untitled

  6. Untitled

    Untitled

  7. Untitled

    Untitled

  8. Untitled

    Untitled

  9. Untitled

    Untitled

  10. purlin split

    purlin split

  11. S

    CH blocked or pump failure?? HELP PLZ

    Hi everyone, so had a check and the pump is spinning fine, and also the pressure vessel is pressured fine too. The CH system pressure remains between 1bar and 1.5bar, the short 22mm pipe coming straight out of the boiler heats up incredibly, however after the Tee juntion, one of the Tee 15mm...
  12. S

    CH blocked or pump failure?? HELP PLZ

    Sorry Kev, yeh water works fine. I was thinking that if the water isnt circulating properly, the water in the immediate area of the boiler is heating up too much and tripping the thermostate due to over heat. The excess steam and pressure is then spat out through the discharge pipe...i could be...
  13. S

    CH blocked or pump failure?? HELP PLZ

    Hot water is working fine.
  14. S

    CH blocked or pump failure?? HELP PLZ

    How did you sort the blockage out out Travis2000?? System is only 3yrs old so is this still a likely problem? Do other guys on the forum tend to agree. Will Fernox f3 cleaner help?
  15. S

    CH blocked or pump failure?? HELP PLZ

    Hi mate, water was very clear with some white clouding in it. All isolation switches ( i assume the small lever taps on the pipes going in and out of the boiler) are open. Hot water works perfect. No sure how to check divertor..is it easy? I am a very good d.i.y'er so if its doable, i can...