    How much access is needed to this connection box?

    None …because sooner or later it will be a fibre optic cable …
  2. sparkymarka

    Veritas 8C Alarm, some buttons stopped working!

    Think the pcb ribbon socket is better on the older ones…
  3. sparkymarka

    Veritas 8C Alarm, some buttons stopped working!

    How come the ribbons on the older 20+ panels never caused an issue ? But the later ones can be a pain ….cheaper ribbon or ribbon connector ?
  4. sparkymarka

    Texecom Veritas R8 Plus

    Totally flat ….external bell rings for bell Cut off time then stops ( depending on external sounder ) power back on panel will start going off , enter code to stop , reset all should be same as before …but it has been know for the Veritas to factory default !
  5. sparkymarka

    Texecom Premier Elite 24 Keypad Mains LED Flashing

    What’s the light doing on the main control panel ?
  6. sparkymarka

    Mum Leaving Plusnet

    Plusnet used to have excellent customer services when it was uk based …but I guess that’s all changed …
  7. sparkymarka

    Eurosec CP8L dead - where to start

    What makes you think the outside sounder would go off after removing panel lid ? Only a down power or bell fuse replacement could set off external bell if it has a battery fitted in good condition
  8. sparkymarka

    Ei141 smoke detector alarm stuck. Not sliding back in fully or back out fully

    Only time I’ve seen this happen on one of these alarms is when …a screw was put into the plasterboard without a plug …it came loose and jammed the smoke head from sliding out …
  9. sparkymarka

    Texecom Ricochet PIR's False Low Battery Error

    Never do that …in my experience you get issues , create a new profile on wintex and manually put in the same settings then upload it to the panel
  10. sparkymarka

    Eurosec CP8L dead - where to start

    Just pop a fuse in …. Also replace back up battery if it more than 5 years old while your in there…
  11. sparkymarka

    Eurosec CP8L dead - where to start

    Disconnect garage keypad , there should be a 680 ohm resistor at the last keypad that needs moving if it’s fitted at the garage keypad ( across 12v and D1) Check fuses in panel probably 2 of F1 1A quick blow F2 250ma quick blow See if the alarm now works , check garage keypad for water...
  12. sparkymarka

    Yale IA series alarm

    Pyronix enforcer piezo is 30mm x 15mm deep
  13. sparkymarka

    Yale IA series alarm

    Look at RS components …