Recent content by tooltime79

  1. T

    Glaxey flex 20 wireless

    Hi all, Probably a really daft question but I am trying to establish how many wireless zones the flex 20 will support and how many wireless devices (assuming can have more than one wireless device per zone)? I have the standard panel with the add on RF board - how many zones/devices does this...
  2. T

    Galaxy flex GX remote app

    This is the extract from the manual for the flex panels, try this: Galaxy Flex/Flex+ Panels • 7 steps for panel programming of Push Notification in panel 1. Set up Server IP Address (Menu 56.1.1.1.4.1= 152.194.72.102 Port:10000) 2. Select Format (Menu 56.1.1.1.4.2 = SIA Level 3) 3. Enter...
  3. T

    Galaxy flex GX remote app

    This is from the setup manual... Galaxy Dimension Panels • 7 steps for panel programming of Push Notification in panel Select Format (Menu 56.4.02.1 = SIA Level 3) and Enable and Select Triggers * Select the events which should be pushed to the Mobile devices Set up Server IP Address...
  4. T

    Galaxy flex GX remote app

    For anyone that is interested I have now managed to get this working. Happy to share with anyone who needs the steps. Thanks Tim
  5. T

    Galaxy flex GX remote app

    Hi everyone, I have recently updated my GX remote app which is connected and working on my galaxy flex 20 (v3.37). The new app provides push notification to the app but requires setting up in the panel. The user guide says: Provide the generated Account Number and Destination IP to your...
  6. T

    Galaxy flex remote keyfob

    Thanks for your reply. I don't think that is one of the options for the flex panel. It was for the G2 I think. All I can see is "RF Fob PA [51.60.2] " which is enabled or disabled. And "Hot Keys [58.6] " which is also just enabled or disabled. Thanks Tim
  7. T

    Galaxy flex 20 v3 SMS user notification

    Just to follow up on this - I have now resolved following a call to Honeywell tech support. For some reason the panel wasn't picking up the SMS message Centre number from the SIM card. Once I had manually entered into the settings and reset everything it seems to be working. Thanks to the guys...
  8. T

    Galaxy flex remote keyfob

    Hi - I have a galaxy flex 20 with a TCC800m remote keyfob installed. The keyfob arms and disarms fine however when I press the two buttons to initiate a panic alarm it only triggers a silent PA. It will send a message (SMS) that a silent PA has been triggered but it won't trigger the external...
  9. T

    Galaxy flex 20 v3 SMS user notification

    I have v3.37. Thanks Tim
  10. T

    Galaxy flex 20 v3 SMS user notification

    Hi, thanks for the reply. I have checked this and I have a mobile number in the first entry. Interestingly in my system it was in menu 42.5 though. Thanks Tim
  11. T

    Galaxy flex 20 v3 SMS user notification

    Hi all - I have just installed the above panel with the AO81 GPRS/GSM module. I can send text messages to the alarm to activate etc and it works, and it will respond with the alarm status. However I can't get it to send a message when the alarm goes off. I have followed the steps in p 147 of...
  12. T

    Potterton Puma 80e DHW temperature/flow problem

    Thanks for all the responses...it sounds like the heat exchanger might have got scaled up as it has been getting worse gradually and the CH seems to be working without too many problems. Think I am going to get someone in to have a look at it as it sounds like it could be one of many differant...
  13. T

    Potterton Puma 80e DHW temperature/flow problem

    Thanks for your quick response! I tried putting the CH on and turned on a tap - the red led did come on. I looked at the flame and it does seem to get bigger...looks like may have to get someone in to look at it! Thanks for your help
  14. T

    Potterton Puma 80e DHW temperature/flow problem

    Hi all, I have a problem with my boiler...the CH is working fine and gets hot, but recently the temperature of the HW has fallen so that the water is only lukewarm, the manual control is turned upto the maximum and the boiler pressure is normal. When the hot water is on, the CH pipes remain...
Back
Top