Hello , I have the above boiler, just recently the shower would be hot then the water would go cold after 3-4 mins the hot water would come back on.
We live in a hard water area, would a descale of the boiler help or is it a valve ? somewhere getting stuck ?

Thanks
 
Sponsored Links
What would that mean if the flame went on and off during the HW?

Thanks
 
Sponsored Links
Hi Ian,

The burner does stay on when the hot water goes cold.

Thanks
 
Hi Ian,

The burner does stay on when the hot water goes cold.

Thanks
well the heat has to go somewhere, turn the CH off and run a hot tap or the shower and feel the CH pipes below the boiler , they will be 22mm ones are either of them getting hot ? if so you have a diverter valve problem
 
  • Thanks
Reactions: CBW
Hi Ian,

Yes one of the 22mm central heating pipes is hot. Is it straight forward to change the diverter valve , I assume its the diaphram that needs replacing ?

Is there a " How to guide " on this forum for changing a diverter valve ?
Thanks for your help Ian
 
Hello ,
How difficult is it to change the diverter valve please?
 
probably just the diaphragm very easy to change and only a few quid to buy
 
  • Thanks
Reactions: CBW

DIYnot Local

Staff member

If you need to find a tradesperson to get your job done, please try our local search below, or if you are doing it yourself you can find suppliers local to you.

Select the supplier or trade you require, enter your location to begin your search.


Are you a trade or supplier? You can create your listing free at DIYnot Local

 
Sponsored Links
Back
Top