  1. B

    PIR Zone not to be used (scantronic 9751)

    Hi all, I've wired up a scantronic 9751 panel, but have decided to leave one of the zones not connected with a PIR as the room is to be decorated soon. What I want to know is do I simply program the zone as 'not used' for now, and loop back the detection circiut wires, maybe using an electrical...
  2. B

    Isolation switch between Consumer Unit & Meter.

    Hey Johnny, thanks for that link. I may consider this over the DP switch/ enclosure option
  3. B

    Isolation switch between Consumer Unit & Meter.

    Thank you for your responses guys. Ban-all-sheds, I did think a 100Amp dp switch will be ok. You ask why a switch fuse? I was thinking maybe if the new tails from metre to CU were going to be longer, then a switch fuse may be necessary to protect the cables. However, I don't think they will...
  4. B

    Isolation switch between Consumer Unit & Meter.

    Hello all, I'm having my CU upgraded(LACB informed), and thought of having an isolator switch fitted. Wondering what is the correct way to isolate the CU from the meter. Arranging the DNO to come & pull service fuse & install an isolator provided by me. I was thinking maybe a 60amp Wylex...
  5. B

    Potterton EP2000 Programmer replacement

    Hi I have an old Brown Potterton EP2000 central heating/hot water programmer. However, I wish to update this as I can only switch on CH/HW at the same time or one at a time. Also, the writing on the control panel is almost invisible as it has been operational for over 25 yrs! I need a...
  6. B

    Central heating problem

    Hi all A few days ago, my central heating would not come on but the hot water was working fine. I have a 3 port diverter valve on which there is a lever which I turned to the right but with no luck. The lever just seems to push to the right wihout any sort of resistance. I opened the...
  7. B

    Pipe banging like mad when hot water is switched on

    Hi its not a combi, just a normal system that you have to switch on the hot water/ central heating manually or through the timer. As mentioned, the breather pipe that comes out of the hot water tank has a tiny little cap on it. Should this cap be closed tightly or be a little loose...
  8. B

    Pipe banging like mad when hot water is switched on

    Hi I've got a preety annoying problem on my hands. Basically, when I switch on my hot water, its begins to heat up with a few minor noises coming from the boiler itself and then after approx 8-9 mins, one of the pipes starts to bang and shake violently! At this stage I have to switch it off...