Search results

  1. M

    Boiler issues

    Can you please explain more please
  2. M

    Boiler issues

    I always thought a combi boiler was a condenser boiler which mine is Anyway any ideas
  3. M

    Boiler issues

    the boilers just over 7 years old which makes it ancient apparently lol. fitted a new expansion vessel at the end of last year. it doesnt seem to have any issues with hot water though. is it common to get signal problems from the wireless stats
  4. M

    Combo Boiler issues

    first thing to check is the balancing as already said next is to check the return tempreture to the boiler the reason for this is alot of new combi boilers have an automatic bypass. you have to check your manual for this. this is why you need a radiator furthest away to have lockshields on to...
  5. M

    Boiler issues

    Hi all have a Worcester Bosch 28 junior boiler. A few weeks ago it started acting up the wireless thermostat called for heat but it fires and runs but the heat is only Luke warm through the pipes Reset the boiler and it's been fine for a few weeks This morning wore up to a freezing house...
  6. M

    Pump speed temperature issues

    I just saw the info from a website with a boiler engineer I presume no concrete guide as such I haven't touched the case on the boiler so unsure what you mean
  7. M

    Pump speed temperature issues

    No where on line says what speed it should be on that's why I asked You can reach the toggle on the pump without disturbing anuthing
  8. M

    Pump speed temperature issues

    What pump speed is perfect for a Worcester Bosch 28 junior combi? I read it must be on 3 but I've turned it down and can't tell any difference? In the cold weather if I set the temp at 19 it gets there easy and doesn't fire that much If I set it higher then 21 it struggles but the return temp...
  9. M

    upvc draught.

    the door is a fair few years old. the corners meet the frame but the middle doesnt
  10. M

    upvc draught.

    my upvc door has a draught at the bottom. i replaced the front and back seals as the back door was bad too. i adjusted the hinges and moved the door closer which has helped but still a draft coming through on looking at the door at the bottom either the door or the frame seem to bow in the...
  11. M

    combi radiator system

    all the trvs are both direction that i brought as i use some as lockshields
  12. M

    combi radiator system

    according to this my boiler has a bypass fitted inside http://community.screwfix.com/threads/does-a-combi-boiler-need-wild-radiator.122261/ the front room radiator where the room stat is on full both ends. it is a trv but its at 5. no issues to report except there seems to be a bit of...
  13. M

    combi radiator system

    the 0.5 is the pressure you need to put into the diapram in the expansion vessel when you fit it
  14. M

    combi radiator system

    can you advise on the expansion vessel pressure. it says 0.5 on the back. the pressure cold is about 1-1.2 bar and doesnt seem to get above 2 bar when running now so its definitely making a difference it says in the manual a static charge of 5 metres 0.5 bar is ok i have no idea what that means
  15. M

    combi radiator system

    thank you that makes sense. as the last radiator is in my bedroom its set to 5. i renewed all the radiator valves and my bedroom does have a trv. i will take it off and fit a lockshield cap. the lockshield side is fully open noticed today the pressure was about 3 bar in the boiler. bearing in...
  16. M

    combi radiator system

    having read up on the web there should be a bypass fitted. theres not and this bit of pipe didnt have one it says if the furthest radiator is fully on which it is that will surfice. seems bypassing via a radiator doesnt seem popular anymore
  17. M

    combi radiator system

    that would make sense but this is the second radiator near the boiler which doesnt make sense at all. the tank was removed and some piping kept which is where i feel the issue was as it looks like its all been joined together i now have a much lower return temp on the boiler but red hot rooms...
  18. M

    combi radiator system

    just to give some feedback on this. with the amount of t pieces we decided against ripping all the pipes out as they run under the bathroom which wasnt accessible we decided to cut the 22mm section out and fix the piping to the front room when we stripped the floor boards up we found this...
  19. M

    combi radiator system

    the temp is the heat coming off the radiator i used a probe. or the temp of the radiator itself the lounge radiator is helped by higher temps on the boiler but balancing means i end up turning the rads off rather then getting a good temp at the rads near the end with the rest on luke warm. im...
  20. M

    combi radiator system

    in the pic the arrow to the left is to a rad by the boiler in the toilet the diagram doesnt show any weird t pieces that are scattered. all pipework is 15mm
Back
Top