Search results

  1. M

    Picture lights and ceiling track lights

    Up to 50 ,hrs there’d be too much work with them
  2. M

    .

    Some have used quinetic switches for the lighting rewire Less messy anyhow although i’d still prefer solid wiring to gadgetry myself
  3. M

    Impact wrench trigger fault

    I had a load of dust inside a combi causing trigger issues managed to open and clean it A Bosch 18v sds with trigger issue they took and Fixed it , great service
  4. M

    Shop warranty process

    I was mainly concerned about doa but sh1t happens after too Any nonsense of posting things to be tested is way too much trouble
  5. M

    Picture lights and ceiling track lights

    You could string 12v wires and fit the spots where needed Doesn’t look too bad
  6. M

    Shop warranty process

    A microwave I was looking at I noticed the warranty process is you send it back by post at your expense Would that be the norm . My thinking was I’d bring it back to shop but the customer info says not to bring it back
  7. M

    I'm confused about junction box rules

    The problem then with the accessible joins is that you basically need a map showing their location when troubleshooting At least if you walk into ANother unknown installation and everything is terminated at points ie; socket , switch ,light , you can troubleshoot by working with the clearly...
  8. M

    I'm confused about junction box rules

    The problem with ring final socket circuits in general is that they’ll be branched off in various ways regardless of regulation At least with a radial final circuit the fixed wiring is protected
  9. M

    Electric shower wiring, does this look ok?

    My bad sorry I thought you said wiring to shower was bigger than internal Internal wiring is sized to load
  10. M

    Electric shower wiring, does this look ok?

    That mostly doesn't matter Internal wiring is sized to load
  11. M

    Ceiling Extractor Fan Kit for Shower Room

    Agree with all above if you're fitting inline get a good powerful fan with overrun Ducting pulled tight not just fired up like a snake
  12. M

    Electric shower wiring, does this look ok?

    What's the heat and flow going to be like on that It's only 6.9 kw at 230v
  13. M

    To all those that welcome/encourage the small boat migrants.

    Trump would stop the boats "in a day" He actually would too
  14. M

    Surge protection?

    I think most domestic are “straight to busbar now “ Better job
  15. M

    Ceiling Rose - Is this Ok?

    I said surface led with space not ceiling rose Anyway either method is acceptable and it’s a difference of opinion In this particular case its 3-plate with branches It’s simpler to troubleshoot or disconnect a fault on a branch there when it’s readily accessible rather than looking for joints
  16. M

    Electric shower wiring, does this look ok?

    A layer of silicone across the top is ok imo, stop water running down the back Not all around as the back dissipates heat, probably a warranty fail anyhow Installer said the Mira can be damaged as a result Don’t know about Triton they’re generally superior to Mira im told
  17. M

    Electric shower wiring, does this look ok?

    Seems simple to connect but lots of mistakes are made Type of things you see with plumbers and diy - cpc probably not doubled back - stranded live conducters twisted and inserted - timebomb with connections not adequately tightened
  18. M

    Ceiling Rose - Is this Ok?

    Longtime spark and i wouldn’t generally go that way although nothing wrong with it Creating hard to access joins Simpler testing or troubleshooting when all terminating is done at “points “
  19. M

    Ceiling Rose - Is this Ok?

    Anyway globe or ceiling rose is not the way to go As said above a surface led fitting with plenty of space inside to tidy wiring
  20. M

    Electric shower wiring, does this look ok?

    CPC not fully sleeved As above get spark to check , tightness . fault loop etc
Back