Search results

  1. R

    under worktop socket afterthought.

    Hi, I am soon to get the utility room (part of new extension) plastered and put some units up and the Mrs has changed the plan for the washer/ dryer. Instead of going into a unit stacked on top of each other she wants them under the worktop in the utility. I did not plan for this and have no...
  2. R

    Washers for Condensate trap Greenstar Utility

    Hi Boiler is Greenstar Utility 18/15 oil burner. I hope someone can shed some light onto my leak on the condensate trap. There was a drip coming from the trap and pulled the washers out to inspect and have now lost them. I can't even remember if it was an o ring or rubber washer. I visited two...
  3. R

    Framing wall for pipes or unit in bathroom

    Hi I am about to tile the floor of my small bathroom,a mate is helping me out. Before I do this I need to get some plasterboard on the walls so as not to get mess on the floor tiles. I thought of putting a unit in to cover the pipes for sink and maybe toilet but haven't got my finger out to...
  4. R

    CH pipes and water pipe run.

    Do you think its worth cutting and extending the CH pipes so that they are moved up a few inches away from the water pipes toward the wall plate timber? I am not sure how much of an issue its going to be,
  5. R

    CH pipes and water pipe run.

    Good shout I have used these before. Ill have to keep thinking!
  6. R

    CH pipes and water pipe run.

    So If I put the cold water on the bottom clips and the hot the one above it is this far too close? I thought with heat rising and all the cold on the bottom would be best. I could route the water pipes above the CH but thought this a bad idea also.
  7. R

    CH pipes and water pipe run.

    Hi I am linking up CH pipes for UF heating and running hot and cold water into extension. I have them all heading to the same corner and don't want them too close. The water pipes are below CH pipes and need to run above them to get to bathroom. The only thing I can think off is to aim the CH...
  8. R

    Lights looped in switch

    Great info guys. Yes I meant cables.
  9. R

    Lights looped in switch

    Hi I am just wanting to confirm if I loop lighting circuits through the switches I will have three wires at the switch. Main in, main out and switch wire. I need to run one main light cable and a switch cable to each light fitting? Thanks
  10. R

    Bathroom extractor ducting run

    Hi I have purchased an inline extractor fan as I was advised that these are good https://www.toolstation.com/airvent-100mm-mixed-flow-inline-extractor-fan/p70282 It will be going in a small bathroom. I will position it in the middle of the bathroom as to get above the shower there is a noggin...
  11. R

    Fused spur new build 350mm?

    Good point! My BCO has been very reasonable throughout and seems to use common sense. Yes I know, I am lucky!
  12. R

    Fused spur new build 350mm?

    It's a new extension though so is inspected by building control. Everything will be checked by an electrician just wanted make sure I was putting things in the right place!
  13. R

    Fused spur new build 350mm?

    I don't think part M applies to me as mine is an extension and not a new build. Does this sound right?
  14. R

    Fused spur new build 350mm?

    I did yes. I though I had read it somewhere but looking again it looks like it's just 150mm? Part M maybe I'm not sure this is a snipet. .. "To enable access by wheelchair users, outlets, switches and controls should be at least 350 mm from room corners"
  15. R

    Fused spur new build 350mm?

    Hi I need a switched fused spur to supply underfloor heating wiring. I take it I can put this nearer than 350mm to a wall corner seeing as it's not a socket and won't need touching regularly ? I wanted to include it in the ring final also would this be ok it's the wiring for thermostats and...
  16. R

    Cable clipped above insulation?

    Hi I need to run some cables over some insulation boards. Is it ok to clip T & E onto plywood that is on top of the insulation I.e the cables are above the insulation clipped with d line clips...
  17. R

    32mm hole in stud 4 x 2

    No insulation.
  18. R

    32mm hole in stud 4 x 2

    Yes
  19. R

    32mm hole in stud 4 x 2

    Joists are 8 inch so I think the hole for these is OK it's the non load bearing stud work that's 4 x 2. Maybe do 2 smaller through these?
  20. R

    32mm hole in stud 4 x 2

    No sorry that's my fault you are right the leg for the return is the other side of building. It's 1 x 2.5mm, 1 x 10mm and 1 x 1.5 or 1mm for lights.