  1. X

    Anyone know where i can get one of these, or similar?... RCD

    ...me too. But it is not 'unsafe' as such, and if you aint got the money.....
  2. X

    Why dose this happen? tumble dryer/rcd question

    ...Some RCD's like to just keep tripping once they have been tripped. Same thing hapened to me. I changed a lighting circuit sligtly - RCD tripped. Put everything back to how it was, then activating the shower tripped the RCD.
  3. X

    Anyone know where i can get one of these, or similar?... RCD

    ...no, the incomer is a 100A breaker.
  4. X

    Anyone know where i can get one of these, or similar?... RCD

    ..The 50A is for the shower. Current for this actually works out to around 38A. The 32's are rings - up,down and extension. Up and extension is low use.
  5. X

    Shower on separate RCD - will it help

    ...I did some more investigation tonight. With everything dead, I did a continuity check between the neutral at the switch and all the neutrals on the RCD side of the CU. 2 of them were positive. - upstairs ring and downstairs ring. So it seems that the lightswitch neutral is connected to 2...
  6. X

    Anyone know where i can get one of these, or similar?... RCD

    ...great, thanks again. (this is connected to my other thread - The present RCD takes a while to re-set, and also, I thought it may be worth trying, just in cast the old one is no longer performing properly).
  7. X

    Shower on separate RCD - will it help

    1. The RCBO on the non-protected side is a good Idea. There is a spare way but the busbar does not extend into it. Can i buy a new busbar? 2. All the lights were already there. We had a problem soon after we moved in, so I took the wall lights off. I only connected new lights back up...
  8. X

    Anyone know where i can get one of these, or similar?... RCD

    ...Thanks matthew, It is a Volex CU - VCU6.
  9. X

    Shower on separate RCD - will it help

    I recently wired up some wall lights/ceiling lights. (Wall lights had never been connected since I moved in). Anyway, i think there is a bit of neutral-borrowing going on, but the wiring in the place is a nightmare (JB's under floorboards etc). I don't think I could sort it out without re-wiring...
  10. X

    Anyone know where i can get one of these, or similar?... RCD

    Morning! Does anyone know what if there is a brand of RCD that I can use instead of one of this Volex, or where I could get a Volex RCD? Tried a couple of local wholsalers who were not very helpful. I do not want to disconnect until i have a replacement as down-time is an issue. Thanks Alex
  11. Untitled

    Untitled

  12. X

    3V from capacitive coupling?

    Hi John, As you say, I really doubt that the capping is earthed (I'm surprised there is capping at all!). I will check the N-E voltage when I get home. The switch is a 2-way 3-gang, but only the 1-way are being used. There is one supply into the switch and the other 2 gangs are linked at...
  13. X

    3V from capacitive coupling?

    Thanks Eric. I'm guessing then that the only other thing it could be is low insulation resistance resistance on the lighting cable.
  14. X

    3V from capacitive coupling?

    Just taking an aspect which did not get answered in a previous thread .... can the galv capping on a lighting cable buried in a wall, measure 3V between it and the Neutral of the circuit, as a result of capacitive coupling? Thanks
  15. X

    3-gang switch, non-RCD circuit tripping RCD, etc.

    ...Thanks Spark. There is a separate MCB for the lights (not on the RCD way). You are right though, the runs are all over the place.
  16. X

    3-gang switch, non-RCD circuit tripping RCD, etc.

    Morning all, I tried to fit 3 wall lights last night to existing cables. Lights have not been connected since I moved in. A 3-gang switch controls 2 ceiling light and 3 wall lights. The ceiling lights each have their own switch so I assume the 3rd controls the 3 wall-lights. 2 lights are...
  17. Untitled

    Untitled

  18. X

    Fault-finding ...Dishwasher involved

    ...OK, Sounds good. Thanks. A
  19. X

    Fault-finding ...Dishwasher involved

    Morning all, My friend has asked me to have a look at a double-socket. He recons that when he plugs the dishwasher in, the RCD trips. Also, there are signs of heat damage (black) on the socket. So, it could be the dishwasher with a leakage current or a loose connection in the socket...
  20. X

    Spirit level calibration

    ...ok, thanks for the responses. Believe it or not, the question was as a result of looking for a good quality level, and finding that even some of the expensive ones have adjustable vials for easy calibration! As mentioned above, all i need to do is turn the level around to see if the bubble...