  1. R

    Boiler/pump making stange noises??? Please help!!!

    Yep thats your problem mate, pump is goosed which without it causes the water in the system not to circulate therefore leading to the boiler overheating and cutting out the pilot light (safety measure). Water coming out of the exp into the tank is caused by the water in the boiler overheating...
  2. R

    Thorn Boiler m30/42B

    But why would you ask someone to order a part for a job that you were going to do?? especially if you knew what you were doing? even more so when the cust doesn't have a scoobie what they are ordering. First time on this forum tonight but I reckon some folk are just on here to give people the...
  3. R

    Wet room probs!!!

    Thanks mate, been on and ordered a BAL tanking kit, some proper BAL adhesive and apoxy grout. Just need to ply the floor and work out how to get my run for the drain, any ideas??
  4. R

    Thorn Boiler m30/42B

    There is a difference between him doing jobs on the side and someone not knowing what they are doing mate,yes they both still maybe illegal in the eyes of the HSE but only one of them is likely to end up with safety issues. (assuming the forementioned "plumber friend" didn't know what they were...
  5. R

    Wet room floor

    Any ideas where I can get this Bal stuff??? Is it just applied by brush then left to dry? once dry then tile onto it with waterproof grout? Whats the best brand of grout to get?
  6. R

    Fitting Central Heating *now with plan*

    I'm afraid I agree that unless you know what you are doing a complete install is a big task. I personally wouldn't touch a job to install a boiler on a system which has been fitted using limited knowledge and a bit help from the net. Far too many probs to be had, you would spend more time fixing...
  7. R

    Wet room floor

    Pass, told me it was Apoxi grout? the stuff they use on swimming pools etc. He just tiled directly onto the 22mm chipboard flooring, no ply or sealer was used by the looks of it.
  8. R

    Wet room probs!!!

    By construction I take it you mean how the original was laid? when Ilifted it it was just two layers of tiles (to get correct height for drain I assume?) and tiled straight onto my 22mm flooring no ply etc.
  9. R

    Worcester 24i strange fault

    Yeah you can measure the pressure across the APS, and see what you are getting. As I said before any probs with the flue/fan etc may cause insufficient pressure to make the switch.Hope you are CORGI reg? as there could be an obvious fault that only a trained eng would spot, there is also the...
  10. R

    Wet room probs!!!

    Hi guys, need a bit advice reg my tiled wet room floor. Had tiler come in and tile my floor with a Mcalpine drain fitted. About two months later the tile grout cracked and they began to move, surprise surprise tiler nowhere to be seen!!!!! I have lifted the tiles myself and found the floor...
  11. R

    Wet room floor

    Hi guys, need a bit advice reg my tiled wet room floor. Had tiler come in and tile my floor with a Mcalpine drain fitted. About two months later the tile grout cracked and they began to move, surprise surprise tiler nowhere to be seen!!!!! I have lifted the tiles myself and found the floor...
  12. R

    Worcester 24i strange fault

    Alright mate, if you have cleaned the venturis I would be looking at the flue and checking for blockages, also make sure the fan is running as it should as if its running slow the APS won't make. There is obviously no fault with the ignition sequence if it is firing up when you make the APS...