  1. C

    New oven and hob

    Well, thanks again for your help on this matter. it appears that for the £5 cost of the dual plate, plus some cable, I'll be good to go. I guess then final check will be to ensure that the 6mm2 cable goes right back to the consumer unit, which I am almost certain it does.
  2. C

    New oven and hob

    So, when shopping for oven and hob we found a job at 7.2 kw and an oven at 6kw. We were told that they would require separate 32amp supplies and also questioned the size of the cable to our existing oven. They also said they would not install the items if on arrival the existing installation...
  3. C

    New oven and hob

    Wow! Thanks for all your help!
  4. C

    New oven and hob

    So, so long as the hob and cooker are less than 15KW, I'm good to go with current installation?
  5. C

    New oven and hob

    Why do they not? Is it as simple as you dont have everything on at once? (all 4 hob rings, plus oven plus grill) But what if you do? Christmas day?
  6. C

    New oven and hob

    I'm now finding internet pages that tell me that a standard cooker installation with a 32A mcb / fuse can cope with 15KW? Can anyone explain?
  7. C

    New oven and hob

    Just done a few calcs.... If supply is 240V and max MCB is 32A, then max wattage of oven and hob would be 7.6KW, which means the above will cause an overload????
  8. C

    New oven and hob

    We have yet to choose the oven and hob. We are aware of 13 amp plug hobs, but also been told that they are not that powerful. A quick scan of the market shows that i could buy an oven with a rating of 5.9KW and hob at 7.2KW. It surprises me that the rating of the oven is less than the hob, but...
  9. C

    New oven and hob

    Looks like I will be having a new double oven and an induction hob. Both are likely to be 32 amp. I currently have one 32 amp mcb in the consumer unit that feeds the existing cooker. This should be fine for the new oven, but what about the hob? I know I could get a 13amp hob, but most are 32...
  10. C

    Needing a laugh? But serious problem - HELP!

    Update. Wife had the idea of heating the water via the immersion as it might expand the coil or soften the plastic wire. Yet right..... It worked.!!! Simples really. Just got to unblock the cool now!
  11. C

    Needing a laugh? But serious problem - HELP!

    Ok, This is related to a previous post. It appears that i have a blockage in the primary coil of my unvented cylinder. I know this as I have taken off the inlet and outlet pipes of the coil. The feed pipe is clear and the return is to. I cant blow through the coil - or suck - used a wet vac...
  12. C

    Vaillant Eco tech 624 system boiler not heating water.

    Thanks for input!! Have you seen my update?
  13. C

    Vaillant Eco tech 624 system boiler not heating water.

    Update. Repair man came today. 1. Said hw control valve was broken, so replaced it. But still no hot water. 2. Said air lock in primary coil so tried to vent and bleed. No good. So then tried to "drag" water up to the cylinder via a hose attached to the vent of the primary coil. Still no...
  14. C

    Vaillant Eco tech 624 system boiler not heating water.

    Thanks for reply. Yes, plenty of water pressure. If faulty valve can they be fixed easily?
  15. C

    Vaillant Eco tech 624 system boiler not heating water.

    Hi, We have an Eco tech 624 plumbed as a system boiler. It has a pressurised hot water tank in the loft for hw. Come back off holiday to find that the boiler appears not to be heating the hot water. It fires up for the programmed time but no hot water. Non of the control knobs have been...
  16. C

    Plumb sure 15x10 internal reducer

    Hi Bought some internal reducers for converting my 15mm rad valves to 10mm pipe. Was a little confused by this brand and the set is one piece, rather than two piece and an olive. I finally worked out that this one piece type does not need an olive, even though the instructions on the pack refer...
  17. C

    Very heavy radiator

    Hi Trying to hang 48 kg rad to brick wall. 3 brackets appear ok, one is going into either mortar or a very poor block. Tried moving the bracket but still the same problem. Any ideas? Also a bit concerned with the screws and plugs supplied. Are wall anchors ever used. All good advice...
  18. C

    Hinge spacers on UPVC door

    Thanks for the suggestion and link. Possibly could work but I would prefer to make my own spacer so it would be white and match the profile of the hinge. Pity I cant get an answer as to why such a upvc product does not exist. I wonder if the concern in cantilevering the door off the frame...
  19. C

    Hinge spacers on UPVC door

    Hi Im told that nothing exists what so ever to pack out flag hinges from the door and its frame on a uPVC door. After some alterations a uPVC door no longer opens much past 90 degrees as the hinges hit the new surround - effectively the door is set too far into the wall now. A simple solution...
  20. C

    Insulating under ceiling

    Thanks. Was indeed thinking of doing the outside wall. But no easy way to insulate above ceiling hence question about below.
Back
Top