Search results

  1. C

    Do they make a Flexable flow & return pipe for boiler.

    That might be an idea. I was trying to avoid touching the pipes in the area where they are fixed as its sods law its where all 3 MV's are & where pipes go though beams & alike, so would have problems even raising the pipes a few milometers, but can cut into the flow & return.
  2. C

    Do they make a Flexable flow & return pipe for boiler.

    Hi, thanks for the reply. Unfortunately its a Glowworm sxi30 boiler with a built in pump that couldn't even be removed & mounted remotely. But you opened up other idea's with those clips.
  3. C

    Do they make a Flexable flow & return pipe for boiler.

    Hi, got a small problem with noise transfer from the boilers pump to ceiling. I have put in my own heating in a bungalow with the boiler & tanks in the loft & pipes dropping down to the rads all done in plastic except for the last 2 meters to the boiler which is in copper. (All is working...
  4. C

    LPG or Oil

    My fault on the tank, we would of had to have a pump fitted for the oil as we couldn't work it on gravity & that added a few hundred with the pump & added electrics. The boiler was a 30kw sealed system basic boiler (none combi) as a 21kw would not have been enough. We where a little lucky on...
  5. C

    LPG or Oil

    I know its an old thread, but i just fitted a boiler for my new central heating system & the boiler cost me £702.00 to buy in comparison to nearly £1500.00 for the oil equivalent. Wile we have a JCB on site we ordered a 2400lt underground tank that cost £407-00 from Avanti gas & will hold 2000lt...
  6. C

    Max Lenth 22mm condensation pipe from a boiler

    Hi, we are fitting a boiler & are about to fit a 22mm condensation pipe from the boiler to a waste pipe in the bathroom, but the length of run is around 11 meters with a nice slope. What is the maximum length this can be in 22mm?. The only info with the boiler is that on a long run, increase...
  7. C

    Are the Texecom Premier ID biscuit's the same as Honeywell's

    Hi, having trouble locating some Texecom Premier ID biscuit's to work with the 60 id expansion card. Are these the same as the Honeywell ones so i could use these instead? Thanks. Chris.
  8. C

    Is the Premier 48-88 memory module still available.

    We was looking to issue 4 fobs or individual codes to staff & 1 cleaner & use it for work time sheets. It would of been nice to have kept a longer record as the unit would of also logged other alarm activity's. But i email Texecom again & they said the 1000 log is no longer made. But suggested...
  9. C

    Is the Premier 48-88 memory module still available.

    AH! That's who i emailed 1st & they replied as just a very short no. But it seems strange that their paper work for the Premier panels says yes & wondered if i just got a newbie on the job.
  10. C

    Is the Premier 48-88 memory module still available.

    Hi, cant seem to find the answer on whether this memory Premier module is still available. It extends the log to 10,000 events & would be real handy for my situation. Has anyone fitted one or seen one. (It apparently fits on the expansion port) Thanks Chris.
  11. C

    Recommended alarm panels ???

    Many thanks guys, i think the 48 looks a real good bet with some better expandability from the 24. I noticed that software is available for these units that gives also the opportunity to local & remote access to the panel with windows. Would this give me the possibility of turning the alarm...
  12. C

    Recommended alarm panels ???

    Hi, any recommended on alarm panels with a good track record for reliability & expandability (20 zone min) Thanks Chris
  13. C

    Part P from a consumers viewpoint

    I would personally would try to find a qualified electrician that has been recommended by a friend that has had them working in their own house. Just because someone is qualified, doesn’t mean they are good at their work or house trained. I have employed electricians in the past that are...
  14. C

    Wiring a contactor

    This might be similar? Just make sure the contactor coils is 220/240 volt.
  15. C

    Is there a Log/Multi fuel fire with outside air supply?

    Hi, we are at the planning stage with a new build & wanted to install a multi fuel log fire with water heating facility’s, that draws its air from outside. The main reason for this, is there will also be a heat recovery ventilation system being installed & didn’t want the log fire sucking the...
  16. C

    Banging pipes problem

    Hi, hope you can help. We have recently had the areas water pressure increased dramatically & we are now getting the problem of pipes banging, especially when taps or washing machine valves turn off. Problem is! This is when our neighbour’s taps & machines turn off as we are on a shared main...
  17. C

    Have you seen this particular window roller shutter?

    [/url] Ah! well done. That "Domestic part" opened up a new world. Thanks.
  18. C

    Have you seen this particular window roller shutter?

    Having trouble trying to find the maker/supplier of some very common window roller shutters/blinds that looks very much like the roller shutters on garages & shops, (but more refined). The ones that i have seen are very common in France/Italy/Spain & hotter countries. They can be mounted...
  19. C

    Pyro

    Hi, try a place called Massgrove electrical wholesaler's at 13 Brent st, Hendon NW London. Their place was there before the ark & has got me out of trouble a few times. They even have the old original wooden ceiling blocks for light fittings if you need them.(Original) Phone NO: 02082020005 &...
Back