Search results

  1. G

    Leaking Telescopic Radiator Valve

    The telescopic extensions always leak...the o ring inside fails. Replace it with a solid extension available in various lengths or to be cut down eg...
  2. G

    Glowworm Flexicom 30cx - Should I replace something as a precaution?

    The pump runs for both hot water & heating. I'm not familiar with this model but you could try running the heating for 15 minutes and operating the hot tap a few times whilst it's on. Sometimes air becomes trapped in the boiler over summer (and the internal auto air vent' is either...
  3. G

    Expansion vessel on unvented hot water tank question.

    If he's not easy to contact (within normal working hours) surely it's time to bin him off. You should also note that a dedicated branch fitting must be utilised on the stack...a strap boss (and equivalents) are not permitted. This is from the BPF that represent most of the main pipe...
  4. G

    Valve not suitable for drinking water

    The valve has probably not undergone the tests required for suitability to connect to the public water supply and in this country most quality importers/manufacturers would also seek WRAS approval. Of course that doesn't stop 1000s of suppliers selling unapproved/untested products for the public...
  5. 20250826_151700.jpg

    20250826_151700.jpg

  6. 20250826_151851.jpg

    20250826_151851.jpg

  7. 20250826_151741.jpg

    20250826_151741.jpg

  8. G

    Pump Running, but no demand

    The cyl stat only turns the cylinder zone valve motor on or off. Under a demand the stat would energise the motor. As the motor opens the valve a cam/lever also rotates and operates the microswitch when the valve is nearly fully open. It is this switch that then energises the boiler & pump ( via...
  9. G

    Pump Running, but no demand

    AFAIR the 400 series doesn't control the pump so a failed zone valve microswitch is the 1st item to check.
  10. G

    Expansion vessel on unvented hot water tank question.

    PVCu/uPVC is standard waste pipe...needs to be muPVC or cPVC ...ie. modified or chlorinated PVC.
  11. G

    new boiler cold radiators where does installers liability end

    I would suggest that for many people that couldn't be further from the truth..when did you last apply for a court judgement? 20 years ago when I issued my 1st claim it was far more straightforward but the process is now more time critical and formal. A recent claim I helped our daugher with had...
  12. G

    new boiler cold radiators where does installers liability end

    With the following knowledge you might be able to prompt the installers to resolve the issues with the threat that you'll approach local building control with a non compliant system. Have a glance at Approved Document L vol 1 This is a legal requirement and sections 8.8 & 9.8 refer to...
  13. G

    Best shallow bath trap

    These traps are generally non compliant and you run the risk of drain odours as the water seal is insufficient. There are multiple reasons for loss of trap seal. Normally Approved Document H calls for a 75mm seal unless it drains into a gulley/hopper (ie. it's not under the influence if other...
  14. G

    Leak from cylinder - is it terminal?

    Have a look at the hot outlet connection on top of the cylinder..there's a faint chance it's the source.
  15. G

    Very Low Profile ventilation

    You do realise ventillation requirements of boilers comes under gas safety law...and guessing at it can have serious consequences.
  16. G

    Very Low Profile ventilation

    Ventillation requirements for boilers will often come under "gas work" as they are based on calculations and not guessed at. The sizing of vent holes and vent positioning is also defined. Out of interest what is the exact boiler model and approximate size of this storeroom?
  17. G

    Central Heating Plumbing Question

    You've got the heating equivalent of the internet with so many routes the water can flow. Just rip it all out and lash it back up to get a basic system running. What boiler model?
  18. G

    Why is my replacement TRV not sitting correctly

    You can't fit just the TRV head to the old valve...
  19. G

    Turbos on 1 litre engines

    Remember that many wet belt engines also utilise a wet belt for their oil pump drive..this can also fail and is not always changed. The Puretec engines used on many Stellantis group cars now have a chain conversion kit that hopefully solves the problems for the remaining cars life...although...