Search results

  1. Y

    Conveting kitchen base unit to two seperate units

    I did some checks in the weekend. Stop cock stands up to 170mm, too high; I bought lever full bore ball valve when fitted will be at 100mm high, all dishwaher have cut out of around 80mm and with legs raised will solve this part of the problem. The remaining issue is the vertical pipe needs to...
  2. Y

    Conveting kitchen base unit to two seperate units

    Not the first time he gives wrong info, I've put him on ignore list.
  3. Y

    Conveting kitchen base unit to two seperate units

    I had full size was too big to fill, slimline will be just fine. Hope this helps your curiosity.
  4. Y

    Conveting kitchen base unit to two seperate units

    I don't think I can do my plan, there is the stopcock which come out about 60mm from wall, the whole depth is 590mm leaving only 530mm. The depth of the washing machine is 550mm plus 20mm for the door. I rememberd the old dishwasher was sticking out by 50mm or so. I may need to replump if...
  5. Y

    Conveting kitchen base unit to two seperate units

    It's been like this for 3 years, previous full size dishwasher was used 5 times in 20 years. Slimline is more than enough really.
  6. Y

    Conveting kitchen base unit to two seperate units

    Hi I have an usnused base unit of 615mm space, pls see photo, door is fitted but not in use. I want to convert it to 2 units, one for 150mm pull out and and second for 450mm integrated dish washer. The plan is: 1. Cut the door 597m in the photo to make 2 doors for each of the 2 units: 147mm and...
  7. Y

    Issues with window sill and upstand tiles

    Hi 1. I painted window sills last summer, used leyland arcylic primer undercoat and dulux satinwood paint. Line cracks appeared few months later. I sanded the sills today, photo attached. They are line cracks, will be hard to fill but will try and prime and paint again. Should I do anything...
  8. Y

    concealed dual shower valves

    Yes agree just seen that, brick is about 100mm, to chisel 70mm or so is difficult and not much of the brick is left to fix the valves which are quite bulky and weigh around 3kg.
  9. Y

    concealed dual shower valves

    Hi I will be doing my bathroom renovation soon, external wall is cavity about 300mm total thickness. I'm thinking of installing concealed dual outlet thermostatic shower valve, I don't want a false wall to acommofate the valve, how easy to fit one and maintain in the future? Or just go for...
  10. Y

    Installing dual head shower head mixer

    I think my pipes at 12000mm from floor is a but high can't change it, ceiling hight is 2400mm, it won't look nice if too close to ceiling.
  11. Y

    Installing dual head shower head mixer

    Cutting or modifying the pipes would be a messy job, won't go there. What is the diameter of these chorme pipes? What space between ceiling and horizontal pipe of the deluge is aesthetically acceptable?
  12. Y

    Installing dual head shower head mixer

    I don't think you understood my question. The product height as per screwfix is 1170mm, is this height adjustable, to for example at 1000mm?
  13. Y

    Installing dual head shower head mixer

    Hi I want to install dual shower head, haven't bought it yet but ineterested in the screwfix Swirl range link below: https://www.screwfix.com/p/swirl-bonda-hp-rear-fed-exposed-chrome-thermostatic-multi-head-shower/340xx#product_additional_details_container In the more info says product hight...
  14. Y

    Attaching 2 wine racks

    Hi Is it workable to attach 2 tall 900mm wine racks to make 1800mm wine rack plus 150mm legs? 2 or 4 legs? This will be placed next to a larder unit so can be attached with joining kit. Photos of the rack beow; demensios: 900m x 320mm x 150mm
  15. Y

    CH Pump Problem

    The installer strangely said you can run it at any speed like it's up to me, he is gas safe and did sound knows his staff. But still. It was on speed III but someone on here; may be it was you suggested speed II
  16. Y

    CH Pump Problem

    The pump was set at speed II, noticed the operation is like on the motorway speeding at 100mph, ie: hectic lots happening in the airing cupboard. l lowered to Speed I and now it's like cruising at 70mph and now the airing cupboard is calm. Is there disadvantages at the lowest speed? Any thing...
  17. Y

    CH Pump Problem

    I don't have Magnaclean but planning to fit one one soon. I do regular flushes every year but magnaclean will defo improve system.
  18. Y

    CH Pump Problem

    I was not trying to repair the pump, I was asked to dismantle and see what's wrong. Again in pls read previous post #62 above. So I obliged for all to benefit and experience.
  19. Y

    CH Pump Problem

    I dug further, removed the fan and got the bottom of the issue, broken plastic bits from fan which cause the grinding noises on its last day of operation, assume wear and tear of the material after 23 years plus. The whole impeller is free of sludge or curd which is good news. On the plate there...
Back
Top