  1. sparkymarka

    Menvier TS2400 - reset HELP

    Do you have a multimeter ?
  2. sparkymarka

    Menvier TS2400 - reset HELP

    Did you totally down power it ? Inc disconnecting both batteries ?
  3. sparkymarka

    Menvier TS2400 - reset HELP

    Most keypads have the following 12+ 12- Data ( data transfer ) Clock ( data receive ) If one if the data lines is missing you could get keypad screen key bleeps but no data transfer .., If it was me and all wires are in the network bus ..,,totall down power and re power mains first
  4. sparkymarka

    Menvier TS2400 - reset HELP

    Check you haven’t pulled out a wire on the keypad bus in the panel
  5. sparkymarka

    Texecom Premier Elite 24

    At a guess it’s not programmed for timed exit …
  6. sparkymarka

    Texecom Premier Elite 24

    Post pictures of wiring in control panel and the detector …
  7. sparkymarka

    Texecom Premier Elite 24

    How are the PIRS wired ? 4 wire or end of line ? Also is the setting set to final exit or timed ?
  8. sparkymarka

    Dual Path communicator pyronix

    What’s chance of mobile network going down … it got a roaming sim Or pay a hefty charge for fitting dual com
  9. sparkymarka

    Dual Path communicator pyronix

    Just use the sim based module in the first place …it used to be the GRPS + sim , but they have just changed it
  10. sparkymarka

    Texecom Premier Elite Odyssey 1 External Sounder question

    Totally over the top , looks like you are using G3 bellboxs and have wired them accordingly You need to connect the batteries ( as far as I know ) for the fault relay to clear …
  11. sparkymarka

    Gardtec 800 alarm, change fuse

    Strange thing is …..the end station is a a 816 the keypad is a 580/370 style keypad ….ive never seen that type of LED keypad on a 800 series ? They have allways been the contour LED or the original LED with the small flap to one side ?
  12. sparkymarka

    Bell Box Advice - Flashguard vs Orisec ES-330 vs Pyronix Deltabell X vs Texecom Odyssey X-B

    Best of luck with the flash guard …..don’t think they have made them for years …
  13. sparkymarka

    Gardtec 800 alarm, change fuse

    The fuse isn’t in there …there’s a plain box about 20x 15 cm probably a plastic one all the fuses are inside that
  14. sparkymarka

    Honeywell Accenta fault

    Oh dear ….. bin time as the battery resistor is burnt out
  15. sparkymarka

    Honeywell Accenta fault

    ok post pictures
  16. sparkymarka

    Honeywell Accenta fault

    Probably it’s lost 12v +….or tamper switch issue and the bell tamper in the panel is linked out ….also check battery charging resistor as they can burn out with a faulty battery ….post pictures of pcb..