  1. G

    New boiler and gas lead pipe

    Don't be an ar5e...you can plainly see a meter swinging on a flexi and old lead pipe is unsafe and G11 3.11 makes reference to poorly supported pipework.
  2. G

    New boiler and gas lead pipe

    The meter installation is classed as "At Risk". This is an industry standard category and it should not have been left "as is" without some plan of action ie. making safe. It's not a case of "nice to have". Meters and pipework must be adequately supported. Although lead can be left, given it's...
  3. G

    New boiler and gas lead pipe

    Are you happy to be part of his conspiracy to evade tax? It might get very awkward should the job go wrong and you need to issue a CCJ etc. I'd bin him off for for his greed and not including the work it in the quote. The meter needs a bracket to secure it and the lead replaced with copper...£10...
  4. G

    Driving in France

    Many toll booths around Normandy have now gone and they're using ANPR to track you, Payment must be made within 72 Hrs here https://www.sanef.com/index-en.html No need to create and account, very quick and easy. The speed cameras that I came across recently (over Granville way) are fairly...
  5. G

    Back 105 HE Correct Valve Pins

    The pin rises with the pump running..it's part of the safety system ensuring sufficient water in the primary heat exchanger and the pump is circulating. Differential pressure (between the pump inlet and primary hex outlet) is applied to the diaphragm below the pin. I'd first check the filter in...
  6. G

    Hyundai Plate Compacter (Wacker) HYCP9070 Info Thread

    I've got a Hyundai quiet air compressor..it does the job but the quality is dire. They badge up junk. I don't trust the cylinder (so much rusty water when draining) after only 18 months. The threads could have been cut with a grinder they're so poorly formed.
  7. G

    FCU not permitted for immersion heaters, really?

    Here's common heater fitted to some unvented cylinders...there's barely room for 1.5mm cable.
  8. G

    FCU not permitted for immersion heaters, really?

    In this case the 2mm extra diameter of the larger cable makes it impossible to fit safely...the cable clamp will not accommodate that size and due to the ever decreasing size and cheapening down of immersion heaters the cores would be under significant strain when routed from the clamp to the...
  9. G

    Condensate pipe freezing

    Is the pipework compliant with the boiler installation instructions? Further guidance here https://www.google.com/url?sa=t&source=web&rct=j&opi=89978449&url=https://www.hhic.org.uk/uploads/5FF598A848C3F.pdf&ved=2ahUKEwj48fz0x_aPAxV2QkEAHSq2Hm4QFnoECDEQAQ&usg=AOvVaw3O3KhHVQAXJJvbKWXcV5em There...
  10. G

    FCU not permitted for immersion heaters, really?

    T&E has never been acceptable to feed an immersion heater. I'm only talking round cable here. On a recent job the cable clamps supplied with the immersion heaters were not suitable for the existing 2.5mm² round cable....so the contractor binned off the cable clamps and left the elements with no...
  11. G

    FCU not permitted for immersion heaters, really?

    The cable clamps inside immersion heaters are often designed for a maximum cable size of 1.5mm² so is it compliant to use that sized cable with a 16A MCB alone (and no FCU). I'm after answers from qualified electricians...
  12. G

    Pump Running, but no demand

    Often the spring lugs break off and the valve doesn't fully return leaving the microswitch closed despite the motor being unpowered.
  13. G

    FCU not permitted for immersion heaters, really?

    Everyone ok with using 1.5mm² to the immersion heater (that's what the cable clamps designed for) on a 16A breaker?
  14. G

    Pump Running, but no demand

    Push the black button in on the side and remove the actuator...
  15. G

    Pump Running, but no demand

    A very common fault on Drayton actuators is for a return spring mounting lug to break off. If you unclip the head (unless it's a very old type) you can normally pull the end of the spring through the case hole.
  16. G

    Tribune HE PRV 3/6 bar to 3/8 bar

    Get him to whatsapp a pic of it...illegal to work on unventeds without it.
  17. G

    Tribune HE PRV 3/6 bar to 3/8 bar

    Have you asked to see his G3 card?
  18. G

    Tribune HE PRV 3/6 bar to 3/8 bar

    AFAIK Kingspan just buy in and rebadge the cylinder and now that Range are in administration offer no support. https://www.rangecylinders.co.uk/ There are several merchants that specislise in parts for these cylinders..you will have no trouble obtaining correct parts.
  19. G

    Tribune HE PRV 3/6 bar to 3/8 bar

    Even the whole inlet set is rarely more than £50. The control inlet set for older cylinders often becomes obsolete but the cylinder manufacturer will have alternatives. Whilst an 8 bar expansion relief is normal for some cylinder makes I can find no reference to the Tribune ever having anything...