  1. davelx

    How do I wire this a socket?

    Indeed. But I've never come across one.
  2. davelx

    Converting a double socket - do these parts exist?

    There isn't anything, no-one makes a two gang FCU or a two gang with one FCU and one socket. You'll need to enlarge the the hole horizontally and fit one of these: 1-1-gang-galvanised-steel-back-box-35mm or you could look at grid systems but chances are you'd still need to enlarge the hole and...
  3. davelx

    How do I wire this a socket?

    They dont usually, as I suggested in my post. That doesn't mean never.
  4. davelx

    How do I wire this a socket?

    He didn't say that he wouldn't. He said: " IF the chosen socket faceplate is metal AND IT HAS A SEPARATE/DEDICATED earth connection for the face, that should be linked up to earth TOO" i.e. as well as the normal earth connection. Although all the metal faceplate sockets I've seen link the...
  5. davelx

    Merge In Turn, why does no one do it properly!

    Coming off the A3 eastbound onto the A238 heading for the A24 at S. Wimbledon there is a 2>1 merge with a junction on the left just where the lanes merge, and >90% of the time I go through everyone does it correctly and it's seamless. So maybe there is hope!
  6. davelx

    What car did you learn to drive in?

    Instructor's Beetle, parent's Morris Minor 1000 (trafficators!)
  7. davelx

    small air compressor usage

    I use mine for a nailer, a stapler, a riveter, occasional paint spraying, blowing the power saws clean, and impact wrench.
  8. davelx

    Trying to identify my underfloor heating cold tails

    Ah, I missed that. Still seems expensive for a radiator and a fan!
  9. davelx

    Trying to identify my underfloor heating cold tails

    £398.00!!!!!! Try this for £85 https://www.tlc-direct.co.uk/Products/HEPFH2400.html
  10. davelx

    Domestic Aircon power supply

    Given that compact type A double pole bidirectional RCBOs are now readily available for the major CU brands at close to the same price as other types, I can see no reason to install anything else unless there is a specific requirement for a different type. Or am I missing something?
  11. davelx

    Domestic Aircon power supply

    That's not the type, it's the differential current trip rating. Post a photo of the front face of the RCD and we should be able to tell from the markings.
  12. davelx

    Redundant copper line removal

    Thanks for posting that link! I filled in the form about 2 hours ago and they've just called back and I'm booked for 3 weeks time. I'm impressed.
  13. davelx

    Fuse box tripping?

    No, that's a Telewest cable TV box, now taken over by Virgin. The electricity feed will be underground.
  14. davelx

    MPPT Recommendations to Charge 12V AGM Battery from 455W / 36V Solar Panel?

    You can use their sizing calculator: https://www.victronenergy.com/mppt-calculator
  15. davelx

    MPPT Recommendations to Charge 12V AGM Battery from 455W / 36V Solar Panel?

    If you want a proper job: https://www.victronenergy.com/solar-charge-controllers/smartsolar-100-30-100-50 but it's about £75 plus VAT.
  16. davelx

    Consumer unit keeps tripping ourlt

    The first thing you need to do is what pete01 wrote in the first reply - though I would turn each one on individually. Then you'll know which circuit has the problem. Let us know the result and we can give further help.
  17. davelx

    Mum's single oven wired correctly??

    You need a table that applies to the cable you use. It doesn't matter what the heading of the table is. 4E2 applies to H6242B - the manufacturer's data sheet says so.
  18. davelx

    Ethernet cable for internet: over roof?

    https://www.tlc-direct.co.uk/Products/CACAT6EXTslash1.html You need to make sure it is appropriately secured so that is doesn't move about and chafe in the wind etc. You can get armoured versions both in CAT5E and CAT6: https://www.tlc-direct.co.uk/Products/CACAT5EslashSWAslash1.html For the...
  19. davelx

    Mum's single oven wired correctly??

    This cable: H6242B and Table 4E2 but then there is the question about the associated accessories.
  20. davelx

    Fixing TT earthing problems and gas bonding for an EV charger

    Taking hand to hand resistance as typically 1000Ω, using your example above the touch voltage at the fault would be 52.5V and the current across the body 52mA - so very likely fatal, less likely but not impossibly so if RCD protected due to the route of the current through the body.