Search results

  1. Bigsosij

    Tag reader

    And enable level set
  2. Bigsosij

    Tag reader

    Is level set enabled? Is keypad and tag reader both allowed to disarm area b?
  3. Bigsosij

    Tamper alarm

    Yes will need relearn all devices to new panel and obviously program up. What version is the current panel
  4. Bigsosij

    Remove bell box

    U will need to disconnect the 12v supply for the bell box from the control panel, and also disconnect the bells internal battery. And link out the tamper return if u will be needing to use the alarm in the meantime
  5. Bigsosij

    Pyronix enforcer v11

    One of the devices has gone into tamper, and now restored. Should tell u which device in the logs
  6. Bigsosij

    Pyronix Euro 76 - Arming Area / Alarm trigger issue(s)

    It's in the installation manual rather than the programming manual
  7. Bigsosij

    How to program Pyronix Enforcer Wireless Magnetic Contact for shed

    When you are programming the code in the manager area, when going through the options you will set which areas the user has access to. So select C only
  8. Bigsosij

    How to program Pyronix Enforcer Wireless Magnetic Contact for shed

    Yes I would probably use a seperate code assigned to c only. Then set your keyfob to set/unset a and b only
  9. Bigsosij

    How to remove Pyronix Euro 46 Alarm System

    Not without ladders. SAB cable is for the external bell
  10. Bigsosij

    How to program Pyronix Enforcer Wireless Magnetic Contact for shed

    U will select the areas for each zone in the 'change Inputs' menu.
  11. Bigsosij

    Pyronix Enforcer Area help

    Also set your timers, exit mode and volume settings accordingly for area D
  12. Bigsosij

    Pyronix Enforcer - Tamper Error /Admin password reset?

    Strange how it only happened when u changed the battery. Have u walk tested the other devices to make sure they are communicating OK?
  13. Bigsosij

    Pyronix Enforcer - Tamper Error /Admin password reset?

    Yes that sounds good. Did u take the device to the panel location and check the signal ? You will also need to recalibrate the shock sensor if you can get it learned back on. Arrow on inertia barrel should be pointing upwards and 1 click negative before u do this.
  14. Bigsosij

    Pyronix Enforcer - Tamper Error /Admin password reset?

    Are the 2 wire links fitted on the terminals at the end ?