Search results

  1. R

    Texecom smartcom cloud led flashing

    Ideally when faced with a router change, just giving the new one the same SSID and password, will allow everything that did connect to reconnect as normal. The latest firmware for a smartcom is 4.x, so I can only assume you mean control panel firmware which is 6.x the most recent. What procedure...
  2. R

    PIR swap

    The bell/sounder isn't connected correctly, assuming its an externally one-the tamper for that is connected to the global tamper terminals, it shouldn't be-why there are two cables associated with the sounder circuit is anyones guess. The detectors haven't got any tampers connected, those...
  3. R

    JSB Regalsafe RS125 Assistance?

    I've just messaged you mate.
  4. R

    JSB Regalsafe RS125 Assistance?

    Hi, I have copies of the installation and user manuals, I can email to you if you want?
  5. R

    Honeywell Galaxy - Tel line fail and no master code (but have engineers code)

    Yes you can reset the manager code from within the engineers menus, also from engineers you can turn off line fault monitoring, but at this time of night the exact processes elude me, I'll have a further gander during normal waking hours . That is unless others are more awake than I.
  6. R

    Texecom Premier Elite 64w - wireless expander

    1 The system should see the changes and ask you to confirm devices. 2 Recommended, but I rarely power down, as long as you're careful (but I have been installing Tex equipment for 20 years). 3 Yes.
  7. R

    Help needed on connecting USB-COM lead to texecom premier elite 48.

    The usb com is just a data connection to the panel, no need to do anything apart from plug it in. If I did what you suggest every time I worked on a system.....well I'd never get any work done, lol.
Back