  1. boilerdoktor

    Green star heatslave 12/18

    Wiring diagrams pal, both available on line for boiler and stat
  2. boilerdoktor

    New oil boiler and Evohome

    Poor advice pal, all wb oilers come mid setting, and often its just a matter of setting up air ratio to put it to 18 or 25 kw. Agree with simond, wave is only compatable to the heatslave 2 combi. And agree with dan, oilers dont modulate
  3. boilerdoktor

    Worcester oil Heatslave 20/25 tripping RCD in house

    Worcester charge a fixed fee of £260 which guarantees the fix, if to ever get quoted above this figure, consider calling the manufacturer out
  4. boilerdoktor

    Worcester Greenstar Junior 28i leaking - advice needed

    I dont think you get a flow adapter with the manifold supplied which is probably the part causing the leak. In any event its a very easy fix, shouldn t take you much more than half hour
  5. boilerdoktor

    Worcestor GreenStar Lockout

    op you d have saved a pot load by getting worcester out from the start!! they do a one off fix fee. following your DIY route with no experience or correct kit for measuring co2,oil pressure etc I imagine you ll be spending a few more quid before its actually fixed :roll:
  6. boilerdoktor

    Buderus 500 28C leaking

    its a common fault...worcester bosch must be gutted at having bought them out!! although their commercial boilers are very good, the domestic ones are crap! if you phone Worcester they ll do it for a fixed price! It'll be the plastic bottom manifold
  7. boilerdoktor

    Worcester 24 Ri intelligent controllers?

    intelligent controls are compatable with the cdi classic and compact range of conventional boilers sorry meant system boilers both top boilers
  8. boilerdoktor

    Life of Combi boiler.

    Worcester bosch = 20 years plus Most others 10yrs
  9. boilerdoktor

    Worcester Danesmore RS 20/25 LOCK OUT

    my guess and its an internet guess is the solenoid! thing is its all very well to sort your boiler out but can you test the co 2 emmissions after and set it up right?? whats the o2 ratio? ( your looking between 30 -40 % ideally) co 2 is nice at between 10 -11 do you have a co monitor? i...
  10. boilerdoktor

    worchester bosch classic or compact

    Simond your post was post of the day for me pal! To the OP both excellent boilers and I ve fitted 1000's with very few probs. worcester really do offer a no quibble guarantee unlike many other manufacturers. If you have plenty of room around the appliance go for a classic, but if its...
  11. boilerdoktor

    New Install - Combi Boiler Recommendations

    worcester Bosch all day long, quality product imo
  12. boilerdoktor

    Worcester Greenstar 28 CDI Cold DHW

    check your shower is compatable with a combi. did your old system take hot water from a cylinder? or was it a combi? does the boiler go to reset?
  13. boilerdoktor

    Icos HE24 problems

    ahh good point dan haha, thats the system one i believe :oops:
  14. boilerdoktor

    Icos HE24 problems

    expensive the pumps on them, in fact all parts are for ideal boilers, a pcb is well over £200 so much for a cheap boiler, they get their money off you in the long run :evil:
  15. boilerdoktor

    Unvented Solar Cylinder

    worcester bosch do cylinders, i ve just got one to fit with solar, it even beat plumb centre own on price and i get £100 cashback ...result! :D
  16. boilerdoktor

    gas safe engineer quotes

    the only bad 1 i ve ever fitted/looked after is the 26cdi extra, about 10-15 years ago but they didn t sell that many, they then brought out the HE and HE plus which really were the rolls royce of boilers. all the old ones were good, the 350,280 and 240
  17. boilerdoktor

    Which storage/high flow combi?

    Worcester 440 or 550 fiited loads, brilliant boilers and you ll get a 7/8 yr warranty if fitted by an accredited installer :D never had one break down but nice to have the back up if req'd
  18. boilerdoktor

    Worcester Bosch 40Cdi Bad Vibration

    i ll bet any money your people checked the flue gases on max but not minimum. that will be the problem, it should be 9.8 max and 9.2 min. think they ll find minimum at about 7-8 it sounds like a beginner playing the trumbone?
  19. boilerdoktor

    Worcester bosch 28i expansion vessel losing pressure?

    if the expansion vessel is faulty, the press relief valve opens and loses water outside, you need to check that the 15mm copper pipe coming from the boiler through the wall outside isn t dripping. so fill it again and check that which model boiler is it plse
  20. boilerdoktor

    Vaillant Ecotech boiler; CH, but no hot water; need new one?

    no, not all call vaillant and get a fixed price repair? have you any paperwork or do you know exactly what parts need replacing?