Search results

  1. T

    Ideal classic RS40 not staying on burn.

    Check the solenoid coil resistance when it refuses to fire.
  2. T

    Ideal classic RS40 not staying on burn.

    If you have voltage at the MFV the stat is not the problem.
  3. T

    Ideal classic RS40 not staying on burn.

    Wind your neck in Ian .....I was referring to the bloke who could not fix it !! I have never aspired to being an "Engineer". The only letters after my name have been C..nt **** Bast.. etc. I am a mere Plumber / Gasfitter.
  4. T

    Ideal classic RS40 not staying on burn.

    He is NO fookin Engineer!!!
  5. T

    Ideal classic RS40 not staying on burn.

    Is the Multifunction control valve energised .
  6. T

    Oil Burner Safety Control (TF830.3) - red light was on .......

    It would be a sound move to replace the coil and capacitor first Cheap and the capacitor can be fitted loose without removing old one .
  7. T

    Using the solar coil on a twin coil hot water tank for solid fuel rayburn back boiler?

    A Thermal store is the norm for a uncontrolled heat source
  8. T

    Is my pipe/rad layout poorly designed?

    Is this a one pipe system
  9. T

    Red coloured debris in oil boiler combustion chamber

    FGT on a Camray 5 are very low. It is probably condensate rusting the baffles . Nowt to worry about unless return temp is low causing back end rot.
  10. T

    Oil Burner Safety Control (TF830.3) - red light was on .......

    No easy way unless you are present when it locks out.. EB1 will be no spark during light up . Coil will be an attempted re ignition during a burn and an d an o/c coil which will return to a few K after cooling. If the motor does not run on heat demand then misalignment of the pump ( 3...
  11. T

    Oil Burner Safety Control (TF830.3) - red light was on .......

    It could also be the BFP coil Or the EB1 failing intermittently,
  12. T

    Best way to connect these 3 pipes

    Run the 110 into the stack with a 92 junction just below the vent and use the lower branch to fit a blank and boss as suggested for the other two.
  13. T

    Ecoflam minor replacement

    Which boiler do you have? Fitting a replacement burner is more work than a repair. It is not a quick fix option.
  14. T

    Heavy duty waterproof jacket

    Get a Barbour Waxed Cotton, It will last years.
  15. T

    Laying a slate hearth on limecrete.

    I have used gobbo to bed all types of hearths including Marble. If there are any porous joints seal with PVA to prevent staining due to capillary action
  16. T

    Retrofitting a upstairs and downstairs zones, to existing CH system

    Yes! That should work ok ......If it is working now. Dead legs are not good so keep them as short as possible and /or bleed valves. Where is pump and m/v's on system,
  17. T

    Turning off hot water unvented

    no its mains pressure.