  1. T1GERIII

    Routing Cat6 cable CCTV

    Probably inaccessible eaves roof space above there, best to run cable in protective conduit to a more accessible space
  2. T1GERIII

    Is visonic getting obsolete

    Find me a professional installer who still installs Visonic over the other systems…. Ends argument
  3. T1GERIII

    Access to Texecom through Wintex

    All details can be gained through engineers menu you need panel model , system version , udl password
  4. T1GERIII

    New build alarm install

    Pyronix enforcer all day
  5. T1GERIII

    Pyronix enforcer

    it’s not clear what exit modes you have selected for A and B. You have listed the options that are available
  6. T1GERIII

    Pyronix enforcer

    You have two sensors on the landing? One of them is programmed off your night set (B) and one of them is on both full set (A) and night set
  7. T1GERIII

    Is visonic getting obsolete

    Visonic are rubbish and outdated - Pyronix / Texecom all day
  8. T1GERIII

    texecom app

    Texecom has received reports of Texecom Connect V1 displaying a "Server handshake error". We are investigating the fault, which appears to have started on Saturday. It is not occurring on all Android devices, and Iphone appears to be unaffected. We will update further when we know more. In...
  9. T1GERIII

    Video Doorbell for Pyronix Procontrol + App

    EZVIZ doorbells are compatible with hikvision NVRs I believe
  10. T1GERIII

    Pyronix enforcer false alarm

    Set meter to DC check across positive and negative on each PIR for a voltage reading should be above 12v dc
  11. T1GERIII

    Pyronix enforcer false alarm

    Enforcer systems can only take two wired zones
  12. T1GERIII

    Wireless Panic Button

    I believe it’s just a N/C pair from output B to your desired zone
  13. T1GERIII

    pyronix alarm - wireless low batt

    The SMS server that the panel is using maybe shutdown. You need to check how it’s set up in ARC settings
  14. T1GERIII

    Pyronix hyrbid alarm

    Pir require 12v 0v then either EOL (two wires) or all 4 depending how you’re wiring. So minimum 4 wires needed
  15. T1GERIII

    Wireless Panic Button

    Yes put one on a ur2-we this week
  16. T1GERIII

    Pyronix delta bell. Strobing but no sound?

    As above, zone 33 or 34 will be what you need to program for the tamper dependant where you wired it
  17. T1GERIII

    Pyronix Enforcer - Wireless JammWZm issue

    60% of burglaries are avoided just by having an alarm. Unless you are in a rich and high crime rate area you are extremely unlikely to encounter a burglar who is a) not an opportunist and b) clever enough to operate a jamming device accordingly to successfully break in.
  18. T1GERIII

    Pyronix Enforcer - Wireless JammWZm issue

    As above old sensors can cause this and also low batteries in local wireless devices. Another cause of jamming is newly installed LED street lights. turn wireless jamming to 000 and have done with it.
  19. T1GERIII

    PowerMax Visonic - Landline

    Yes it will work as a stand alone bells only system. You’ll need to disable the communications inside the engineer menus.
  20. T1GERIII

    Texecom adding another ricochet expander

    I second the method of deleting the first expander and relearning all onto the 32 way. We have had a couple of sites where the supervision issues are constant on two 8xp, swapped them for a 32 and no more problems fully meshed