    Bit of help with stat wiring please

    Its a Vaillant, system boiler, But I was just going to connect into the wiring centre. No need to go into the boiler It should be straight forward, adding another zone. But I don't get the diagram.
  2. S

    Bit of help with stat wiring please

    Been left this to wire up by the plumber Im OK with wiring heating systems (Generally), but this has got me a bit confused Its a UFH manifold with a two port valve and pump, that need to be added to an s plan I have attached the wiring diagram Pg2 I presume that I take the grey and orange...
  3. S

    Green electricity

    The cost in CO2 from the beginning to end, I would think would be very difficult, to calculate. Just ball parks Im after really. Client wants to stop using gas, and move over to electric. But as pointed out electric is increasingly made from burning gas. So an example. The client wants to...
  4. S

    Green electricity

    Just looking at the C02 emissions per kWh of electricity and gas. Figure from the web tell me that Gas produces 0.185 kg of CO2 per kWh Electricity 0.309kg of CO2 per kWh Does anyone know if they are correct, as it suggests that using electricity over gas produces more CO2 Reason I ask is...
  5. S

    Pyronix PIR wiring

    Could some one please explain whats happening here. Its the Pyronix V10. Im trying to understand alarm wiring. Im don't understanding the circuit, the two resistors share a common connection How does the loop work. I hope that makes some sense Thanks
  6. S

    Using adhesive to fix track lighting to concrete ceiling

    Small job installing track lighting in a 1940s block of flats, with concrete ceilings. Bit concerned about drilling into the concrete ceiling, and hitting something. Some pretty good adhesives around now, so, considering gluing the track up, or possibly VHB tape (Which Ive only just found out...
  7. S

    Table 53.1

    But do you get RCD's with such a high trip current. In 7671, 300mA seems the highest. Im sure in the industrial / specialist world all manor and scale of things happen.
  8. S

    Table 53.1

    Maximum I delta n 20A for a 2.5 ohm (RA) A 20 A trip current for an RCD, or have I misunderstood. Thanks
  9. S

    Touch voltage confusion

    Thanks EFLImpudence, for taking the time to explain
  10. S

    Touch voltage confusion

    I get a bit confused about touch voltage calculations. As this ramble will show. Especially when it involves supplementary bonding. So the resistance between exposed conductive parts and Extraneous conductive parts has to fulfil this formula RA x Ia < 50 v So in a bathroom. Ia is the...
  11. S

    Ryefield Boards

    Thanks very much Flameport, great stuff.
  12. S

    Ryefield Boards

    Thanks Flameport. I completely agree with your assessment. I wonder though how you would code it on a EICR. Only a C1 or C2 will possibly cause some reaction from a management company, a C3, well , i bet thats put away in a folder. The asbestos thing, will cause some doubt. But electrically...
  13. S

    Ryefield Boards

    Thanks for the replies, really appreciated. I won't be pulling anything. On the subject of this type of distribution board. I would like to know more about its function in the supply chain, and who is responsible for it. Is it normal for the Ryefield type board to have no isolation? (That is...
  14. S

    Ryefield Boards

    No i don't think there is an isolator to the LLS But the trunking is rammed, so really difficult to follow cables Most of the isolation for the supplies to the flats contains ceramic fuses The LLS contains ceramic fuses. There is no three phase isolation for the MEM board When you say rather...
  15. S

    Ryefield Boards

    it opens without a tool, big thumb screws. had a quick look in, closed it. just wondering about what to do. speaking with the client tomorrow. the LLS i want to change probably has the same asbestos pads.
  16. S

    Ryefield Boards

    Inside the board The trunking above is packed, really difficult to follow the tails, though it is labelled on the door, but how correct that is 5th fuse on yellow no labels
  17. S

    Ryefield Boards

    Not sure yet Cu is tight up to metal trunking, there is a meter above, but, they are quite a few. I need to follow the tails to see what goes where, have a look inside the trunking
  18. S

    Ryefield Boards

    Landlords CU needs changing. I normally get an isolator fitted if I change a CU. It looks like the CU is powered from the Ryefield.
  19. S

    Ryefield Boards

    Generally who owns these. Its after the main cut out so I doubt the DNO are interested. I guess it depend on if it before or after the meter. What would be the consensus on pulling fuse from a Ryefield You would need to be able to identify the correct fuse to pull, but is this still...
  20. S

    Fire ratings for down lights

    I was testing a ground floor property, in a Victorian four storey house with self contained 2/3 bedroom flats. Single stair case Ceilings are wood joist with plasterboard. Inside the ceiling void is insulation supported by chicken wire. Down lights are installed through out the property...