  1. Jajodu

    central heating is working, but no hot water

    check the cold water cistern in the loft. i bet it's empty.
  2. Jajodu

    Boiler losing pressure (no leaks in pipework)

    primary heat exchanger leaking would give those symptoms.
  3. Jajodu

    Vaillant Ecomax Pro or Myson MPE222 problem?

    Press the ibutton on the boiler when it happens, whats the s code shown?
  4. Jajodu

    Leaking tower radiator

    You'll need to rebleed afterwards.
  5. Jajodu

    Leaking tower radiator

    Thats just a blanking plug, screwfix sell replacements in pairs, bleed and blanking plug. Shutoff both radiator valves, opdn the bleed screw and let as much water out as you can, have some towels handy and remove the p!ug and replace, you mayhave to dig out remains of the old washer, I always...
  6. Jajodu

    Boiler won't repressurise

    I would have if I could have found them.
  7. Jajodu

    Boiler won't repressurise

    Teach me to look at the pictures with something bigger than a mobile. Sorry JohnD
  8. Jajodu

    Boiler won't repressurise

    Disagree herewith flow and return are the two left hand pipes, only one of which has a handle
  9. Jajodu

    Boiler won't repressurise

    The rh black valve is for the filling loop if my eyes don't deceive me,
  10. Jajodu

    Boiler won't repressurise

    As above, black tap at 90 degrees to the body, isolating valve screw head across the body, that's the water off, then keep bleeding one rad til pressure drops to 1 bar.
  11. Jajodu

    Boiler won't repressurise

    Bit high for cold, is this a hot or cold reading? If cold bleed a rad until the pressure drops to about 1 bar. If hot wait until the boiler cools and check then.
  12. Jajodu

    Boiler won't repressurise

    Boxes should read hoses.
  13. Jajodu

    Boiler won't repressurise

    Can you see the screw head on that fitting? Put all the boxes back on, open the normal tap and turn that screw so that the slot is inline with the valve body, your system will then re pressurise. Take it slowly, you don't want to over pressurise
  14. Jajodu

    Boiler won't repressurise

    Has the boiler connection where the flexhose fits got a valve screw in it? The photo obscures that fitting.
  15. Jajodu

    Boiler won't repressurise

    The one way valve that the flexhose connects to maybe stuck, a sharp tap or poke inside with a suitable tool to see if you can free it up. Was it a decent flow from the hose?
  16. Jajodu

    Boiler won't repressurise

    Make sure both of those taps are off, then remove the filling loop at the boiler end, place it in a bowl and slowly open the tap, does anything come out? You may have a frozen pipe.
  17. Jajodu

    HE24 Boiler 0-3bar gauge range

    Look here on the method. https://www.diynot.com/diy/threads/faqs.37170/
  18. Jajodu

    HE24 Boiler 0-3bar gauge range

    looks like the expansion tank needs repressurising
  19. Jajodu

    Replace Danfoss Tp4000

    Honeywell lyric t6r?
  20. Jajodu

    VAILLANT ECOTEC637

    Press the I button on the panel and observe the codes as it goes through the sequence, your installation manual will exp!ain what they mean,