Search results

  1. W

    Sealed System Worcester Bosch Boiler With Banging Noises in Storage Cylinder

    It is a Gledhill cylinder, vented to loft cold tank (450x1050).
  2. W

    Sealed System Worcester Bosch Boiler With Banging Noises in Storage Cylinder

    Ok, so the Boxt appointed engineer came out. Good bloke who carried out a thorough investigation. Upshot was it was the coil pipe inside the hot water cylinder come loose. Of course, no way to fix that other than to replace the whole cylinder. He said he'd only ever seen that issue once. I'm...
  3. W

    Sealed System Worcester Bosch Boiler With Banging Noises in Storage Cylinder

    Got the Boxt appointed engineer coming out on Saturday as it's still under warranty. Had it installed end of Feb this year. Has taken till Oct to get this problem. We used the central heating for a few months after installation without any issues. Over summer just had it to heat the hot water...
  4. W

    Sealed System Worcester Bosch Boiler With Banging Noises in Storage Cylinder

    Thanks. Yes, it's an unvented system with an expansion vessel in the same downstairs cupboard as the boiler. Not sure of the make and model.
  5. W

    Sealed System Worcester Bosch Boiler With Banging Noises in Storage Cylinder

    Have a 6 month old Sealed System Worcester Bosch 4000 Ri Boiler system with Storage Cylinder. When it heats water or rads, getting banging noises from the hot water cylinder. Got engineer coming to look at it (under warranty) in a couple of days but wanted to be clued up as to what the issue...
  6. W

    New heating system weird behaviour

    It's looking like the issue was the lever on the diverter valve actuator was catching on the foam around the cylinder. He's cut the foam back now, so hopefully that will help.
  7. W

    New heating system weird behaviour

    Didn't exactly admit he did wrong. He actually said that Boxt will have to pay him more to come back and sort it out. Don't see why they should if by the sounds of it, he cocked it up. But not my money paying for him, so don't care. Hopefully get him round this week.
  8. W

    New heating system weird behaviour

    Turned out my theory was wrong. Heating engineer said he needs to come back and do some repiping. Something to do with the towel rail in he bathroom. Don't quite understand though. I know initially the towel rail came on with the hot water. Now it comes on with the central heating which is...
  9. W

    New heating system weird behaviour

    Could it be that as the pumped shower is emptying water from the cylinder, the boiler is fired to replenish the hot water in the cylinder. All normal. But there is some issue with the controls, telling the diverter valve to send hot water to the rads. Although, in this case sounds like the...
  10. W

    New heating system weird behaviour

    I think it only does it when the shower comes on.
  11. W

    New heating system weird behaviour

    I will but do you have any suggestions what he could have done wrong? Or what the issue would be?
  12. W

    New heating system weird behaviour

    Have just had a conventional boiler and cylinder system installed with sealed central heating pressurised filler tank (rather than old style small header tank). Had it a week and am finding that when the central heating is off but someone has a shower, the upstairs radiators come on. The...
  13. W

    Trv valve off but radiator not cooling down

    Just had complete new boiler installed and as part of that had all radiators fitted with brand new trv valves and lockshields. However, am finding that when the trv is set to off for a particular radiator when the heating is on, that radiator is not cooling down at all. Same for all...
  14. W

    Cold water header tank lid

    I have an old 1960s rectangular plastic cold water header tank. Currently it has some old planks of wood on top and some thin plywood on top of that. All very mouldy. Id like to get a proper lid for it. Preferably plastic. It measures 880mm x 790mm. Any ideas? Thanks
  15. W

    Brown water from hot water taps

    Was hoping for better after job customer service from the big companies as I typically haven't got from the local people I've used in the past. Basically, fixing any issues. Time will tell though. You might see me slagging off British gas or Boxt on here in a few weeks.
  16. W

    Brown water from hot water taps

    British gas Quoted me £5723 for 15kw WB conventional boiler in the larder cupboard. Waiting time of 3 weeks. Awaiting Boxt to try and do better. They can fit in a few days though. Had never heard of Boxt until recently but my research shows them coming out better than British Gas in all respects.
  17. W

    Brown water from hot water taps

    Thanks. Certainly does make maintenance difficult. The CH header tank sits right above the cold water tank ball valve. When I've woken up I'll take another look and go through your message on detail. Things should all get resolved when I get the whole system and all tanks etc replaced. Got...
Back
Top