  1. O

    Increasing water pressure options

    300 litres at 6 bar!! Cost is normally prohibitive about 3k. The main only does 9ltrs/min on that job.
  2. O

    Attaching fence post to house wall - DPC required?

    Little tip..being a plumber i have found the fischer bolts that are supplied used for fixing wall mounted basins ideal for fixing concrete posts. 1 end goes in to the suppled rawlplug and the other end will take a large washer and supplied nut to secure the post...
  3. O

    Setting water and heater temperature on boiler and cylinder

    No set at 70c on boiler and leave it there forever. If you are demanding water at 60c you need a flow of at least 70c allowing for losses unlagged pipes etc. You aim to store it at 60c distribute it at 50c and have it at 45c coming out the taps.
  4. O

    Shoddy combi install, mains water flush microbore a good idea?

    No he still paid peanuts. A decent combi would cost £1200 with the vat (materials) So £1500 is still cheap he got a monkey who screwed him as he did a rough job, didn't flush it properly, didn't put auto air vents and most probably left it with low working pressure on the gas which would...
  5. O

    Shoddy combi install, mains water flush microbore a good idea?

    I wasn't being aggressive I'm answering your post!!. Ouch you paid £1500 for a boiler costing £500 Filter 65 Pipe + fittings £50 Chemicals £0 £615 1 day labour wot £280 £895 Profit. £505!!!! You got screwed.. Whats the benchmark look like and hows your certificate of installation compliance??
  6. O

    Setting water and heater temperature on boiler and cylinder

    The right hand knob on your boiler doesn't actually do anything. Its a commonrail design from the combination boiler. Set your boiler flow to 70c and your cylinder thermostat should be on 60c. You can adjust the cylinder up a down 5 degrees to get it to a level that is comfortable. Cylinder...
  7. O

    Shoddy combi install, mains water flush microbore a good idea?

    You cannot moan about the quality of an install without telling us what the boiler is and how much it cost and how long it took. My point is if you pay peanuts you get monkeys. People want things cheap cheap , but then moan and grown over the cost. I could of fitted a decent boiler with a...
  8. O

    UFH Manifold Leak

    We also cap unused ports with small lengths of pipe
  9. O

    Shower tray movement

    Part of the problem is the release agents they use on the back of the trays when they make them. However if you mix up sbr with cement (no water) and coat the back of tray and the floor before you bed it it will never move.
  10. O

    Mystery Sewer Gas Smell after Extension

    I may have the solution. Looking at the diagram i would be checking the two bath traps what depth of seal are they?? Its very common nowdays for plumbers to fit bath traps with extremely shallow seals as there easy to fit. However let the bath contents go and it will suck out the water trap.
  11. O

    Underfloor heating only luke warm

    My 100watt devimat sitting under granite tiles gets so hot i can barely walk on it. I even used it to bring on tomato seedlings!! A builder should not of laid the heatmat only a tiler/ electrician. Normally the tiler puts it down and then the electrician terminates it and runs the insulation...
  12. O

    Lincat griddle 3kw

    Well that was my first reaction that i reconnected it. However it dawns on me that someone before me disconnected it to get round nuisance tripping.
  13. O

    New purchase Evolution R210SMS+ query

    You can use waste pipe fittings to connect it to hoover. Metabo make the best and often copied compound mitre saws. I just bought the Metabo KGS 18 LTX 216 18v Cordless Sliding Compound Mitre Saw which is great and i also have the big 254mm 230 volt one as well.
  14. O

    Lincat griddle 3kw

    Hi all ive aqquired a 3kw commercial 600mm Lincat griddle. Unfortunately we cleaned it up before fully testing it. It runs of a 13amp plug. At first i had it plugged into my shed circuit which is on a 16 amp radial fed from my garage. It would trip the Rcbo after about 2 minutes, this would...
  15. O

    Silicon sealer

    https://rover.ebay.com/rover/0/0/0?mpre=https%3A%2F%2Fwww.ebay.co.uk%2Fp%2F6014557508
  16. O

    Intergas & Chemicals

    The intergas guys did say you could pretty much run there boilers on custard regards water quality.
  17. O

    Adjusting metal soil pipe

    Could be either asbestos, pitch fibre.. But it looks like lead..look https://www.google.com/search?q=lead+soil+pipe&tbm=isch&client=ms-android-lge&prmd=isnv&hl=en&ved=2ahUKEwjH-qKi487kAhWk1eAKHQcaDsEQrNwCegQIARBt&biw=360&bih=518#imgrc=-WQiJncsBmarCM
  18. O

    Kids have pulled radiator off plasterboard wall!

    Red gripits have a loadbearing of 74kg. Combine that with hatching the plasterboard with a stanley blade and sticking brackets on with clear silicon. :) Or you can cut plasterboard out with multitool..put stud in between uprights and then replace plasterboard and easyfill.
  19. O

    Any leeway on boiler services?

    Most installers are very flexible backdating service dates
  20. O

    Expansion vessels on hot water cylinder. Are they designed to fail?

    You can use blue/white ones (potable) on heating but there twice the price of the red. (Heating) non-potable ones .