Search results

  1. aptsys

    Builder carrying out electrical work - Badly!

    Absolutely no issue with two spurs from one point provided the conductors can be properly terminated.
  2. aptsys

    Builder carrying out electrical work - Badly!

    The installation is appalling, however assuming you mean a spur as opposed to a "radial circuit", there's nothing in itself incorrect about that strategy.
  3. aptsys

    Renting out Mum's house

    As said, the condition may actually be acceptable. Unlikely, but the installation could be wired recently in HO7RN-F rubber flex.
  4. aptsys

    Wiring query, fixing inside light unit

    Yes, strip 10mm of insulation away and just push into those terminals.
  5. aptsys

    Renting out Mum's house

    £3.5-£4k might do it in trunking etc. It would be recommended to spend more than this and get a good install done though with quality parts. That's not strictly true.
  6. aptsys

    100amp fuse overload

    You may need a separate supply for each flat, or suggest other forms of heating, but you don't just add up the rating of every appliance to work out the supply requirements.
  7. aptsys

    Why has my Megaflo tank been installed with a pump on the outlet??

    Yes, the secondary pump realistically can be extremely low flow when installed in the correct place since it only needs to replenish water at a rate that maintains sufficient temperature to each tap. It will be restricting flow where it is currently sited.
  8. aptsys

    Water pump stopped in central heating

    Boiler M8 pumps do not last long in my experience. When you replace the pump next year, I'd recommend going for the genuine Grundfos pump and also having the valves facing the correct way(!)
  9. aptsys

    found this under floorboards

    I think that's TLC's error. The datasheet attached to that product doesn't mention anything about being maintenance free, also on the website for the actual product they're very careful to say they are using "Wago 221 Maintenance Free Connectors" rather than claiming the product is maintenance free.
  10. aptsys

    Rewire double T5 luminaire for LEDs?

    You would probably be better served to replace the fitting with something designed to sink the heat away from the LEDs. Is there a reason to keep the original fitting?
  11. aptsys

    found this under floorboards

    It's using maintenance free connectors, but without the proper maintenance free box, they do not form a maintenance free junction box. There's no MF or BS5733 markings on the box to indicate otherwise. Wago 221 for example require the levers to be held closed by the enclosure, which this box...
  12. aptsys

    found this under floorboards

    I can't see any claim it's maintenance free, certainly no BS5722 or MF markings on the enclosure.
  13. aptsys

    How Do I Crimp This Cable To Add a Bit of Length?

    It's normally absolutely fine. If you look in the datasheet for any mainstream manufacturer it mentions for stranded or solid cable. It actually makes no difference anyway with a properly fitting crimp since when you crimp the conductors, you're effectively deforming a solid mass of copper...
  14. aptsys

    New lights thin wires

    There's a difference between overload and short circuit. It depends on the impedance as to whether it would allow the MCB to trip under short circuit conditions.
  15. aptsys

    Plumber day rate

    Goods are not the same as services though
  16. aptsys

    plumbers mate vs silicone basin waste install

    Never had an issue with Plumber's Mait
  17. aptsys

    Washing Machine Waste Pipe

    Easiest thing to do is fit a washing machine standpipe. Don't just try to box it in. Something like a McAlpine WM3
  18. aptsys

    Socket circuits joined togther... somewhere

    Unrelated to the original question, but there looks to be overheating of the neutrals in this picture.
  19. aptsys

    Is this a lead water supply pipe?

    Many water companies will subsidise the replacement of a lead water supply. Worth checking the website of your supplier.
  20. aptsys

    Old consumer unit , - what are my options to upgrade?

    The OP certainly can.