Search results

  1. G

    Trunking from on top of plaster to on top of wall tiles

    Hi, any ideas how best to lay trunking down a wall where the bottom half of the wall is tiled. i.e. hoew to negotiate the lip where the tiles start? I have thought of fixing a slim piece of timber the same width as the trunking onto the plaster and then laying the trunking on top thereby...
  2. G

    Long Handled Watering Can to help elderly father???

    Need to mix powdered plant food so ned container and plants are at ground level so simply tipping the can wouls be all that was required Thanks for the responses tho
  3. G

    Long Handled Watering Can to help elderly father???

    Hi, does anyone know where I can get such a thing to avoid my father bending to pick up a full watering can? (the alternative would be to raise the height of the outside tap and build a stand to sit the can on when filling) However, a long handled watering can would be the far easier option...
  4. G

    Fence Stain on concrete posts

    Hi, sorry if this question has been asked before, can anyone give me advice on how to clean fence stain off concrete posts? :?
  5. G

    Underperforming Electric Ladder Radiator

    hi, Thanks for the response .. replies are getting more poitive! Please advise on how to measure the current drawn. :? Thanks
  6. G

    Underperforming Electric Ladder Radiator

    Hi, the model I bought is thermostatic sealed with electric element fitted at a cost of £155! This is one of the features of the shower room I did not cut corners on as adequate heat was essential as the room has two external walls and would (and has) become a "no-go" area in the colder...
  7. G

    Underperforming Electric Ladder Radiator

    Hi, I have recently purchased a ladder radiator for my downstairs shower room. It came with an electric element (already fitted and sealed) and a thermostat I fitted separately. Based on the measurements of the room and the passage way outside it (separated by a door), degree of insulation...
  8. G

    Filling a gap in the corner of a shower cubicle

    Hi. I see what you mean and it would work if the tiles were laid vertically but horizontally I would have the sam problem everyy other row. However, due to the thickness of the tiles I was aiming to avoid cutting altogether. Maybe upvc strips against the cubicle edges and a clean joint with...
  9. G

    Filling a gap in the corner of a shower cubicle

    Hi, they are purchased but not fitted yet
  10. G

    Filling a gap in the corner of a shower cubicle

    Hi, I am tiling inside a corner shower cubicle. I am using 33.5cm x 25cm tiles laid horizontally 2 tiles wide on each of the 2 walls. The total coverage i.e. tile + grout + tile leaves me approx 10mm short on each wall. Is there anything on the market like say upvc quadrant to fit in the corner...
  11. G

    Ladder radiator (Fuse for FCU)

    Hi, element was pre fitted and the thermostat/cable supplied separately. No markings on either!
  12. G

    Ladder radiator (Fuse for FCU)

    Hi, I got the BTU from the link below: http://www.lunaspas.co.uk/acatalog/White_flat_electric_ladder_rail_750.html Have I calculated correctly?
  13. G

    Ladder radiator (Fuse for FCU)

    Thanks I take it that generally speaking Watts/Volts = Amps. So, 538/230=2.4, therefore 3 Amp fuse Thanks a alot
  14. G

    Ladder radiator (Fuse for FCU)

    Hi, 1835 BTU using conversion rate 0.293 = 538Watts
  15. G

    Ladder radiator (Fuse for FCU)

    Hi as advised on an earlier post I have wired as follows: 2.5mm to FCU - 1.5mm from FCU to timer - 1.5mm from timer to ladder rad Please advise what size fuse to use in FCU ..... 13A ok?
  16. G

    Please advise on this wiring

    Cheers guys!
Back