  1. chivers67

    Extending loft light

    Get an LED Baton and as Pete says extend off the existing light it's an easy enough job. One thing I'd also do is staple some Silver Radiator Heat reflector foil near the top of the Rafters as this reflects light where you want it..
  2. chivers67

    EICR and fuse box

    Not much a few things but I'm surprised you got an Electrician willing to "Pass" that in 2020. It's a flat by the looks of the title of the JPEG and the fact it only has 4 circuits. They're not labelled for starters the fuse cover is missing which should have those details but sockets should...
  3. chivers67

    EICR and fuse box

    No, is there an RCD unit that protects the installation anywhere?
  4. chivers67

    Cooker hood - hole in ceiling but no duct

    Yes speak to your neighbours and see if they actually have a vented extractor, you'd expect that in new builds these days! You might be able to see if other houses have vents.
  5. chivers67

    Cooker hood - hole in ceiling but no duct

    Can you get some plaster board or plywood and cut a hole in it the size of the hole that's there? Place a piece of wooden batten across the inside with a few inches either side of the hole bridging it and fix this with a screw each side and then screw the circular piece of plaster board/plywood...
  6. chivers67

    Circuit board query

    How did you work that out? A damp cloth was used to clean the fan.
  7. chivers67

    Lead acid battery testers?

    I use a Hioki at work to test the battery impedance(s). If the batteries are over 7.5mohm we replace them as they can't always produce enough current for the UPS to run for very long.
  8. chivers67

    Changed socket and now no power

    Yes I think Wylex you have to toggle completely to the off position & re-energise.
  9. chivers67

    Getting electric shocks in kitchen - immediately after walls have been plastered. (Only when contact made with fresh plaster)

    What's happening with the box top left? It's a plaster board back box with nowhere to go? Personally I join conductors separately into wagos and tuck them out the way protected with some card board. The screw was no doubt touching a live conductor and now it has been removed the insulation...
  10. chivers67

    Front Porch a meter from boundary?

    We'll probably need one though I was hoping to just buy some software to draw up the plans. Think I know a bloke who lives round the corner though. Thanks for the replies. (y)
  11. chivers67

    Front Porch a meter from boundary?

    Hi, We're thinking of having a small porch built with planning permission. It's just over a meter from the Hedge boundary line, it's a semi detached. Our next door adjoining neighbour's house is set back/staggered so the porch will probably be 3 meters from their front wall. Anyone think this...
  12. chivers67

    Another swa to t&e thread!

    Yes, if you read my post I stated you need to use a deeper one the 51mm aren't suitable. I'm fully aware what KO stands for the Wiska's are threaded.
  13. chivers67

    Another swa to t&e thread!

    I'd also use a piranha nut to secure the SWA and link the Earths rather than a banjo & strap. A stuffing gland for the T&E I would also opt for a Wiska as it has knockouts making it very easy to use. A slightly deeper box helps get the SWA fixed too
  14. chivers67

    Need an outdoor socket

    Better to have a small holes drilled rather than notch the top of joists so the cable is less likely to be damaged by someone hammering a nail into a floorboard.
  15. chivers67

    Need an outdoor socket

    Is the floor wooden then? You Can make a spur off any socket for use outside as long as it has some kind of RCD or RCBO protection. I'm not certain what you mean with regards to the nearest socket do you mean it's behind the big Red blob you've marked on the wall? Or is that where you would...
  16. chivers67

    Forgot to drill hole for extractor supply cable behind extractor ? (Ed.)

    An extra long multi tool blade could cut all the top adhesive & short one for grout - I know you can get them at least 60mm which would go some way into removing one without a breakage.
  17. chivers67

    Forgot to drill hole for extractor supply cable behind extractor ? (Ed.)

    From above and below, who knows. Thought the Extractor Hood would go virtually over the top tiles anyway?
  18. chivers67

    Blanking plate

    What that's metal too, a more up to date RCD & without a broken MCB cover? Sounds way too sensible!
  19. chivers67

    Forgot to drill hole for extractor supply cable behind extractor ? (Ed.)

    You might be able to buy a flexible drill attachment to slowly drill through the plaster behind the tile but it will probably cost more than a tile to buy.
  20. chivers67

    Shower extractor fan

    Time delayed fan?