Search results

  1. C

    Pipe thermostat for fan override

    Thanks all, the fan does run all the time in passive mode, I want an immediate purge when the shower is on as the ceiling is low and the room relatively small
  2. C

    Pipe thermostat for fan override

    It currently has a humidity sensor inbuilt but it’s slow to react. Would a liquid sensing pipe thermostat be any better? Drayton stat seems a bit better possibly?
  3. C

    Pipe thermostat for fan override

    Is there a decent sensitive narrow temperature range pipe stat I can use to use as a switched override for a bathroom fan when the shower is turned on? I’ve currently got the flomasta cylinder / pipe stat in place but the water temperature is too low and the measuring type on the stat not...
  4. C

    Vaillant and heatmiser

    Having a bit of difficulty in getting this to work! I have a uh4 heatmiser and a vaillant vr71 Currently ls and lr from the heatmiser are wired to s7 on the vr71 as per instruction from vaillant technical and s6 is bridged. Demand from the ufh system does not cause the boiler to fire...
  5. C

    C300H Countax, engine to PTO belt issue

    Yes that’s the one!
  6. C

    C300H Countax, engine to PTO belt issue

    I’ve given it a good run (my grass is basically a meadow as the machine has been out of action) and the pto belt hasn’t slipped off once so I’m confident it’s resolved. Off to change the transmission fan next as the belt had snapped all the blades off!
  7. C

    C300H Countax, engine to PTO belt issue

    Just coming back to this to share what I hope is the resolution. The four bolts that mount the engine to the frame. One was missing altogether one was missing a nut and had vibrated against the frame causing the hole to elongate and the bolt to bend and the remaining two on the other side were...
  8. C

    C300H Countax, engine to PTO belt issue

    Hi yes it’s the one with the powered grass collector on the back. The pto power comes from the engine via a belt under the chassis see photos
  9. C

    C300H Countax, engine to PTO belt issue

    I'm having a bit of trouble with my C300H. The engine to PTO belt keeps slipping off the PTO pulley at the transmission end. It's a right faff getting it back on each time I want to engage the PGC and wondered if there was any adjustment on the belt pulleys (I've had a good look and can't see...
  10. C

    In frame kitchen integrated appliance

    Bumping this. Leibherr have confirmed their integrated appliances aren’t tested for in frame style kitchen units. They’re the biggest manufacturer of refrigeration so I’m really confused if theirs don’t fit. Can anyone with first hand experience of integrated alliances in in frame kitchens...
  11. C

    In frame kitchen integrated appliance

    The door is inset rather than overlay
  12. C

    In frame kitchen integrated appliance

    Hi, I have a couple of integrated appliances to fit but am struggling to ensure I buy the correct appliance for my kitchen type. The units are solid wood in frame ( as opposed to over lay ) The instructions for all integrated appliances refer solely to inlay and I’m concerned that there will be...
  13. C

    Bcs710 hydraulic leak

    Does anyone have a tracmaster bcs7** series rotavator / tractor that has suffered hydraulic fluid leak? I’ve been told it’s coming from a failed seal between the engine and transmission body but it looks like it’s recently been pulled apart so wondering if it’s as a result of this or someone...
  14. C

    Performance BMS210MS.1Mitre saw issue

    Thanks here’s a couple of pics of the assembly
  15. C

    Performance BMS210MS.1Mitre saw issue

    I've got an issue with the above where by the drive appears to have failed, when I take it apart the end of the armature appears to sit against the inside of the bearing adjoining the gears for the blade assembly but I can't figure out how it transfers the drive, the end of the armature appears...
  16. C

    GJD Dygizone remote light switch override

    Sorry to resurrect this. 0v to a works bit only in mode 1 (detectors operate lights day and night) presumably as the switch sends a signal to the panel but doesn’t reference light level? You mentioned previously a diode, will this make a difference in this instance?
  17. C

    Velux install - handle won’t engage

    The handle won’t engage on a new window (initial steps to remove from frame) I applied some pressure to the handle however the clips will not engage to allow the unit to open. Any suggestions?
  18. C

    Raised path by house

    Just to clarify the path is raised from the adjacent existing path and is formed from a steep slope on the side of a valley. The flower border won’t be raised further than the existing concrete path however. The dpc is approximately a further four feet above the existing path level. My concern...
  19. C

    Raised path by house

    I have a raised path by the front of my house retained by a dry stone wall about four feet high. I’d like to break the path up and repurpose the space as a flower border however I’m worried that the concrete might form part of the foundations for the house. Is there a way I can check before...
  20. C

    Two door bell push with one bell?

    Thanks I don’t know why I thought that wouldn’t work!
Back