  1. C

    where can I buy gate valve stem extensions

    Could somebody please tell me where I can buy gate valve stem extensions? I am retiling my bathroom and replacing the plasterboards with aquapanels. However, this results in the gatevalves being flush with the new tiles, this preventing access to turn the valves. many thanks in advance.
  2. C

    Potterton Profile 80 not firing up

    Just to update. The boiler seems to be working fine now. I am guessing that the part that tripped the overheat function must have cooled down sufficiently enough over-night. However, I perhaps need to drain the system again, as I have read in the manual (at http://www.partsarena.com)...
  3. C

    Potterton Profile 80 not firing up

    I have just recently moved into my new home, which has a Potterton Profile 80 boiler heating a vented CH & HW system. There are 2 HW cylinders located in the loft, below the cold water cistern. Both CH & HW were working fine until I replaced 2 of the radiators, ever since ,the boiler fails...
  4. C

    Honeywell T6360B to CM901 replacement with wiring centre

    It would be ideal and safer to remove the old cabling, however the walls plasterboards adhered to solid wall, and there is no indication of any junctions on the other side of that wall - I assume the cabling runs embedded vertically up or down the wall. Finding where it is still connected to...
  5. C

    Honeywell T6360B to CM901 replacement with wiring centre

    Hi D_Hailsham As I have successfuly tested the CM901 with a 2-core cable to the wiring centre, I have decided not use the original cabling and will make it safe behind a face plate and also at the wiring centre end. I will be running a new 2-core cable between the wiring centre and the...
  6. C

    Honeywell T6360B to CM901 replacement with wiring centre

    I have tested the CM901 by connecting a new cable to the wiring centre, and it works fine. As for the original room termostat cable, even when all 4 wires had been disconnected from the wiring centre, one of the wires at the room thermostat end was still Live upon testing with a mains tester...
  7. C

    Honeywell T6360B to CM901 replacement with wiring centre

    I want to replace my faulty mechanical room thermostat (Honeywell T6360B) with a programmable thermostat (Honeywell CM901) to a system with a wiring centre. I understand that the existing 3-core & earth wiring for the T6360B is for Live-Live Switch-Neutral & earth and is connected to the 4...
  8. C

    Polishing limestone tiles

    I have bought a pallet of limestone tiles for my new bathroom, and am wondering what is the best way to polish some of these tiles for use on the floor. As they are now, the tiles are fairly smooth already, but does not have the polished look that I want for the floor. I have seen a polished...
  9. C

    Require "By-pass Kit" for single pump to DHW????

    I was initially worried about it..cos of the supply to several taps, however after further research into it, I realised that I am ok with the single pump. thanks in any case.
  10. C

    Require "By-pass Kit" for single pump to DHW????

    Does this not mean that all twin-ended pumps should have such a loop? Since, regardless of the number of taps supplied, there will always be times when either just hot or cold supply is required - even when supplying one shower mixer valve. Imagine taking a long cold shower on a hot...
  11. C

    Require "By-pass Kit" for single pump to DHW????

    OK...I think I have found out the answer.... I believe that this only required for twin impeller pumps supplying multiple taps.
  12. C

    Require "By-pass Kit" for single pump to DHW????

    I have just installed a single impeller pump (ST Monsoon 3 br) to boost the DHW to entire house (4 outlets). Do I need one of these ByPass Kits... from http://www.techflow.co.uk/tech4.html Does anybody know whether I need one of these kits ? Many thanks in advance
  13. C

    Possible to transform PosHead pumped system to NegHead sys?

    I am currently renovating my bathroom, and due to tap choice (Hudson Reed's that uses narrow flexi connectors...even for the bath taps), I had to install a single impeller pump (ST Monsoon 3 br single) to boost my DHW, and connnect the taps to the cold mains. Also, the basin mixer tap (15cm...
  14. C

    High pressure showers and combi boilers suitability

    I currently only have a 15mm pipe for my cold mains...when tested the cold at the kitchen service valve, I got 3.5 bar pressure and 15 l/m. is that a normal and adequate supply?
  15. C

    High pressure showers and combi boilers suitability

    Thank you Slugbbaydotcom for your advice..much appreciated. I did misread Vented as Unvented... The unvented cylinder seems the best option...would I need a System gas boiler then?
  16. C

    High pressure showers and combi boilers suitability

    So in order to use one of these HP systems, it is best to have a large cistern & cylinder with a good pump and a decent system boiler? I would need to sacrifice the extra space and also the convenience of the hot water on demand from a combi.
  17. C

    High pressure showers and combi boilers suitability

    Can somebody please tell how I can use high pressure showers (like Hansgrohe raindance shower systems) with a condensing combi boiler ? The Hansgrohe shower requires a flow rate of 28 l/m at 3 bar, however I am struggling to find a boiler on the market that is even close to these...
  18. C

    location for single impeller pump for HW

    Oops....I just realised that I asked the wrong question ([Can pumps only be connected AFTER the pipe connection for the HW breathe pipe? ] I should have asked...Can I connect the pump straight after the hot water cylinder? i.e. BEFORE the branch to the 1st floor bathroom and loft extension...
  19. C

    location for single impeller pump for HW

    I want to install a single impeller pump to boost my HW in my vented system. My cistern tank is in the loft extension, and I am getting 0.5 bar of HW at my 1st floor bathroom taps and virtually no flow from my loft extension basin tap. Would it be possible for me to install a single impeller...
  20. C

    Replacement inspection cover

    My alleyway adjoins to my neighbour's alleyway. I am not sure whether they have a inspection coveron their's.