Search results

  1. mcmarshon

    vokera Mynute and Y plan wiring

    Thanks for the reply EliteHeat. Done a little more looking and what Vokera dont tell you is how to wire the switched live from the Wiring Centre. They only show wiring diagrams using the vokera programmer. From what I can gather now is the switched live should be connected to the 3rd...
  2. mcmarshon

    vokera Mynute and Y plan wiring

    Hi Chaps, anyone installed a new Mynute HE on to an existing Y plan system that has the honeywell sundial y plan wiring centre installed ? Just trying to figure out the correct way to wire the boiler as this configuration supplies 240v to the boiler via the wiring centre on a call to heating...
  3. mcmarshon

    VOKERA. 1st time fit-- crap!

    Which Vokera was it mate. Like to know as I have one to install shortly.........or do I ?
  4. mcmarshon

    Vokera Excell Plate HE

    Thanks for the posts chaps ! In the end I did it on a wing and a prayer. To do this job you need a 12mm and a 17mm allen key, and the 12 mm needs to be long handled as well ! Removing the DHW outlet pipe gives required access to the nut on the plate exchanger, otherwise no chance of geting...
  5. mcmarshon

    Vokera Excell Plate HE

    Already put a full service kit in it. Have a slight pass to heating but main problem is that the h/w goes cold after a while. Presuming the exchanger is scaled up and causing overheat to primary water. What/where are the bobbins you mention, didnt see anything that I could call a bobbin in...
  6. mcmarshon

    Vokera Excell Plate HE

    Thanks for that. Feeling a bit weak now you mentioned the strength bit ! I presume you mention the basin wrench for the access to the nuts. I had considered removing something to get better access (cant remember exact layout and whether removing the gas valve or pump was best) but we'll see...
  7. mcmarshon

    Vokera Excell Plate HE

    Anyone had experience of changing the DHW heat exchanger on the aforementioned ? Note this one is not the normal 'screw in' type - its the rarer model that is secured with bolts/nuts on the heating and water inlets. Only manuals I have are for the more common models that have the two securing...
  8. mcmarshon

    Ferroli Optimax

    Thanks very much for the help Compheat. I'll give this chap a call if it goes off again.
  9. mcmarshon

    Ferroli Optimax

    Dear Corgi Colleagues, gettin a little frustrated with aformentioned boiler, just wondered if anyone has any experience with this 'wonderful' boiler ? Works for a week then pilot goes out and customer is struggling to understand how to re-light the thing. Thermocouple ok, pressure...
  10. mcmarshon

    Cast Iron Soil Stacks

    Hi mnb, with bated breath looked for your post, but cant see it ?
  11. mcmarshon

    Cast Iron Soil Stacks

    Thanks chaps for all the replies. Better get myself down to the merchants to check out this timesaver stuff !
  12. mcmarshon

    Cast Iron Soil Stacks

    I had a feeling that they might be very difficult to cut, and even thought about using my bro's arc welder to cut through it ! I wasnt clear on my original post, but the stack already has a toilet connected. It joins the current stack into what I suppose you would call a 'T' section. Does...
  13. mcmarshon

    Cast Iron Soil Stacks

    Is it possible to break into a cast iron soil stack to add a branch to a new location for a toilet. I was hoping to hacksaw into the pipe and use a plastic branch and connect the new toilet using plastic 110mm pipe. Is this a bad idea ?
  14. mcmarshon

    Insulation of Hep2O pipe

    Nice one.....I'm heading off myself next week......dont worry - be Happy ! :D :D :wink:
  15. mcmarshon

    Insulation of Hep2O pipe

    Good on yer mate, so would I. Seems some people are a bit stressed on this forum !
  16. mcmarshon

    sink waste

    No Mate, just helping out the gas man....he's coming back monday and its just one of the jobs for him to do. Would just like to get some heating back on asap and if it helps..............
  17. mcmarshon

    sink waste

    What parts do I need to connect the condensate drain from a boiler into the kitchen sink waste ? I think the run from the boiler is 1 1/4\\\" plastic. :oops:
Back