Search results

  1. G

    Potterton Suprima controversy

    no we are just asking that people have the applince installed as per installation instructions and maintained as per them as well :? is that really to much too ask :? compare it to taking yourcarto the garage cos your engine has blown up after 2 years and expect a new one the first thing...
  2. G

    Potterton Suprima controversy

    We do play nice music though to give you real value for money :D by the way benchmark books have to be filled out as well where appropriate :? how many of these do you see filled out :shock:
  3. G

    baxi bahama 100 burner pressures

    as long as your waters hot enough dont worry bout i :? if its not probably down to crap in plate h/exch :shock:
  4. G

    noisey BaxiBoiler

    im just too good at this :D should do it for a living :roll:
  5. G

    Noisy Potterton Kingfisher Boiler

    sentinel x200 normally takes about a month if a boiler is really scaled up badly like yours sounds to be try putting another bottle in and leave for alot longer also x200 doesnt have to be drained out :?
  6. G

    noisey BaxiBoiler

    my guess is solo :) anybody else want a guess :?
  7. G

    HELP! Potterton Puma 80e pressure relief valve problem

    if you twist the cap it will come out then spring back try doing this a few times and see if it stops dripping but i have to warn you it doesnt always work and may require replacing as crap (technical term) gets onto the seating ! :?
  8. G

    donut - which way up?

    its a good site mate even for us that think we know it all as we more than often dont :D
  9. G

    puma 80, DHW works, no CH ?

    No youve learnt something new about pumas as this is the only combi i know of that this applies too !
  10. G

    puma 80, DHW works, no CH ?

    yes only takes slight drip from tap to keep the wax capsule in the hot water position :? to test it is that simply turn off ballofix isolator cold water mains into boiler off and see if heating stays on :)
  11. G

    BAXI BAHAMA

    sounds to me like its not sensing flame i assume you have checked that boiler has correct polarity ! live and neutral round right way if thats ok check the air pressure switch ! :wink:
  12. G

    Potterton Suprema 100 Fan

    your right it does have a capacitor but the fan he has does not require a capacitor as its the wrong one for this boiler so he hs 2 options 1.Get the right fan which is of centrifugal type and utilises the capacitor 2.fit the upgrade pcb kit for which the fan he has would then work .
  13. G

    Potterton Suprema 100 Fan

    just would make the boiler 100 % more reliable :)
  14. G

    Boilermate II & Potterton Suprima 40 - Not enough hot wa

    from experience its normally the temperature sensor inside the boilermate that causes the problems :?
  15. G

    Potterton Suprema 100 Fan

    agreed as it sounds like you have the wrong fan but if you fitted the pcb upgrade it would be the right fan :D
  16. G

    Opinions please?

    Baxi Platinum comes with 5 years warranty and i bet you havent had to many problems with the back boiler enough said :D
  17. G

    Powermax 135 bangs when windy!

    sorry if this has been mentioned before (cant be arsed to read back all of the posts) but if this boiler is a 135 model and it has the old style gas valve then there was a recall on it sometime ago which basically means Heateam come out and fit new style gas valve free of charge anyway :D...
  18. G

    Potterton EP 2001 instructions

    http://www.partsarena.com/baxi/ try here
Back