  1. G

    Puma 100 issues

    Sounds to me like a sticking microswitch 21/18867 :wink:
  2. G

    Baxi bermuda HE

    Nickso not sure how that could happen as pcb is on top? Boiler has been out for a couple of years now and all teething problems seem to have been sorted! Heat exchanger is same unit that's used in our Main Combi boilers and are very reliable units! I think they are good units and the other...
  3. G

    Potterton Performa 24 heating cutting out

    Link out the external controls to rule them out first! Then try it with pump disconnected etc till fuse doesn't blow! Then you will know what is the problem :wink:
  4. G

    2nd hand Baxi Bermuda

    This fire cannot be used safely without being attached to the back boiler it was designed tested and certificated to go with! Simple as that :roll:
  5. G

    Powermax flue lagging

    Ha ha the Electromax is essentially 2 products in 1 box ! A megaflo unvented hot water cylinder with 2 immersions ! And an Amptec electric boiler running the heating with both running it will pull around 60 amps :roll: Hence the possible need for a new fuse board or additional 1 :roll:
  6. G

    can i replace my hot water system with this.......

    Also note it only heats water to 38 degrees! Ok for showering but probably not hot enough for washing dishes! :roll:
  7. G

    Powermax flue lagging

    Electromax is around £1600 ! And I would guess around the same again labour wise! Depending on your fuse board and other factors?
  8. G

    Powermax flue lagging

    Yes all owned by BDR Thermea! Best and largest service support team out there :wink:
  9. G

    POWERMAX RANGE 155X

    Check the inlet filter if ok then blending valve is knackered!
  10. G

    Powermax flue lagging

    Regulations state that all joints in the flue should be accessible to inspect! You don't have to fit them on outside wall! I personally would be hesitant to fit a Gledhill with there situation! Go for a Heatrae Sadia Electromax system! Proven quality ;0)...
  11. G

    Potterton boiler only works once!

    From what you are saying i would say it is almost certainly the pcb board(407676) :wink:
  12. G

    Baxi Plantenium 33HE pressure dropping to 0 every 30 mins

    Try isolating the flow and return under boiler this will tell you if it is boiler problem or leak on system! you also wont have any heating! but do it while heating is off over night or something just to find out ! :wink:
  13. G

    Baxi Duo-tec - Diagnosing Expansion Vessel Failure?

    Unless you have pumped water into the shraeder there should only be air coming out ! when they go you can normally see rust mark along the seam at the bottom of the vessel ! :wink:
  14. G

    Baxi Duo Tec frozen - ideas needed

    The thermistor controls the frost protection and if this were faulty it would show up on the display ! I would get the engineer to replace the pressure sensor as i suspect this is at fault! also the boiler frost stat only protects the boiler and not the connecting pipework so make sure it is...
  15. G

    Condensing boiler and condensate

    Yes ! but dont put it outside cos if i get another frozen 1 i might scream :twisted: They freeze easy and are hard to lag!!!!!!!!!!!!!!!!
  16. G

    Baxi 105e

    sometimes turning it to the reset position and back doesnt reset it so try turning it to the off position and back!
  17. G

    Potterton Performa 30 HE

    are there no fault lights appearing!
  18. G

    Baxi combi 80e not working

    At a guess Air pressure switch if not poss pcb!!!!!!!!!!! :wink:
  19. G

    recommendations for a new combi boiler..

    Remeha Avanta + :wink: Nice size boile and good to work on !!! and our new owners :lol:
  20. G

    baxi solo 2 50pf

    You need to fit the pilot kit which includes a differant type off injector which always sorts this problem out for me :lol: