    Baxi combi 80 HE plus boiler

    These lights indicate an ignition lockout which will be caused by the boiler not igniting this can be because of several reasons ! like no gas burnt out spark electrodes faulty ignition pcb or faulty ggas valve not opening :D
  2. G

    Potterton Performa 28i fault

    Try topping the pressure up slightly and checking the auto air vent screw on top of the pump is loose as it sounds like you have air in the boiler :?
  3. G

    Combi - Baxi Instant 105e

    LOL yes thats the Stored water in the expansion vessel :lol: the best way to drain them is to remove the nut off the end of the left hand blanking nut on the isolation valve remove the motor head off the diverter and push the little pin half way down with a stubby! then crack the nut on the...
  4. G

    Baxi ecogen boiler

    BG have an exclusivety on it as they put alot of money into the D & D of it ! it will retail at around £5500 :? They are quite large in size and they do use a sealed stirling engine that comes straight from Japan which also cant be repaired only replaced ! imagine the bill when that goes...
  5. G

    any direct replacements for Potterton EP2002?

    just what i was going to say :lol: Why get a 6002 when you can buy a 2002 or upgrade for 7 day programming and get a 3002 :wink:
  6. G

    Combi - Baxi Instant 105e

    ONLY do this if you are a competent gas engineer as removal of the gas valve is neccesary :? Then it comes out through the front !
  7. G

    poxi bahama 100!! not starting/firing

    Mate the flow switches are all dud's as they were only designed to be used for Air not immersed in water :lol: And i know what you mean about the Bypass tube same as the PRV manifold :wink:
  8. G

    poxi bahama 100!! not starting/firing

    Thats Pants mate should have booked it off like i did :P
  9. G

    Baxi Duotec combi boiler - hot water problem

    The low flow could be caused by the cold water inlet filter being blocked so get that checked! For referance it is possible to change DHW Heat exchanger without removing gas valve but it is a bit tight! and i would recomend getting an engineer in ! :wink:
  10. G

    poxi bahama 100!! not starting/firing

    thats unreal Jason ! Wonder if they know some of the parts are going to be obselete soon :? Wot day you at Conferance Mate ???
  11. G

    poxi bahama 100!! not starting/firing

    Yes me too mate! Normally the Flow switch which stops these things working! And dont tar all baxi's with the same brush the new combi's ie Duo-tec's Platinums etc are superb :D
  12. G

    Baxi Duotec combi boiler - hot water problem

    Sorry i disagree this is always down to crap (Dirt) in system which blocks up the Plate Heat Exchanger ! This cn be cleaned out or ideally replaced! and then clean your system and put a magnaclean or similar in or it will do it again in 6 months :D
  13. G

    poxi bahama 100!! not starting/firing

    didnt you think there was a good reason your mate was getting rid of this embarasment of a boiler :? theres a very good reason it was only manafactured for 3 years!!!! :wink:
  14. G

    Promax 15 HE : sensing tube

    I would go for Heateam as they carry all the parts and have a 96% first time fix Rate :wink:
  15. G

    BAXI SOLO 3

    http://www.partsarena.com/baxi/ Here will have it m8 :lol:
  16. G

    Frozen condensing pipe

    LOL nothing changes with you 2 like an old married couple :lol: Had 8 jobs today with 5 of them being frozen condensate pipes! :shock:
  17. G

    Replacing Baxi Solo 2 with Combi via npower or northern gas?

    He's on about a Promax combi mate totally differant boiler other than the name :? If it was me i would go for a Baxi Platinum combi which comes with a 5 year warranty parts and labour ! and has won several Which awards and orgi awards ! Superb Boiler :D
  18. G

    Opinions on Baxi Solo HE Boilers please

    In 90 % of installations it wont require a pump to be wired to the boiler or the pump over run kit ONLY wire pump to this boiler if it is a fully TRV'd installation with no bypasses of any sort ie 3 port valve! and a pump over run kit is merely a timer which keepes the pump running for a set...
  19. G

    Potterton Performa 28 - No Hot Water

    when you turn hot water tap on is tap symbol lighting up >????
  20. G

    chp

    :D I thought ours were being sold exclusively through British Gas but could be wrong :?