    how to remove temperature dial on thermostatic shower

    With the grub screw removed, it's a case of just pulling off
  2. Crofton Gas

    how to remove temperature dial on thermostatic shower

    That top one on temp is safety button and doesn't come off. You need to undo bottom handle then use Allen key to remove grub screw inside.
  3. Crofton Gas

    IDEAL logic 18 - no pressure gauge

    If it's on an open vent system there won't be a pressure gauge. If it's on a sealed system the gauge would be near expansion vessel. Regards
  4. Crofton Gas

    Ideal Classic FF240 Boiler - Cutting Out

    Lock 3 port valve in mid position, isolate valve under push fit cap, remove push fit and slowly open isolation valve.
  5. Crofton Gas

    Airlock from hell

    Try isolating all the radiators, run pump on full speed, and vent from manual vent near cylinder Regards
  6. Crofton Gas

    Ideal Classic FF240 Boiler - Cutting Out

    Air lock at mid position valve, is that push fit cap on the heating pipework?
  7. Crofton Gas

    Ideal Classic FF240 Boiler - Cutting Out

    Question, when you drained and bled the radiators Thurs, did it take long to bleed rads, could you hear the air coming out? Also if boiler us overheating due to lack of water, you would have to manually reset overheat stat.
  8. Crofton Gas

    Ideal Classic FF240 Boiler - Cutting Out

    That's the ignition striker, it should look as though it's arc internally.
  9. Crofton Gas

    Earth Bonding for shower pump?

    The pump case should be earthed by the supply cable, the pipes are earthed together to maintain earth continuity throughout the pipework as plastic hoses are used Regards
  10. Crofton Gas

    Disconnecting a radiator from micro-bore

    Turning off the other valve will have no effect on the rest of the system, and will only stop the flow of water through that radiator.
  11. Crofton Gas

    Bathroom wastes

    No problem joining the three as they will all have traps and unlikely to be discharging all at the same time. Make sure you use 1 1/2" waste from bath and shower. Regards
  12. Crofton Gas

    Disconnecting a radiator from micro-bore

    You could just isolate the radiator valve on the opposite end and the radiator will not get hot. To answer questions, 1. Trv is on return pipe 2. You do not need to join pipes 3. You will have to drain from the lowest point 4. Pull collar back towards fitting and pull of pipe. Regards
  13. Crofton Gas

    Ideal Classic FF240 Boiler - Cutting Out

    Definitely recommend Paul Daley. From the description it sounds like the heat exchanger is scaled/blocked, you could have it descaled or cleaned through, or worst case replaced, however, the system would more than likely need to be cleaned and correctly treated, if sludge is the cause of the...
  14. Crofton Gas

    Ideal Classic FF240 Boiler - Cutting Out

    If the heat exchangers blocked, it will be replacement boiler needed Regards
  15. Crofton Gas

    Smart Thermostat Help

    Sorry, was thinking of different manufacturer. The wave doesn't need 240v supply but does needs low voltage wiring into boiler.
  16. Crofton Gas

    Smart Thermostat Help

    No, comes with the wave
  17. Crofton Gas

    Smart Thermostat Help

    That would be other suggestion, with worcester wave it's plug and play, you would just unclipped existing timeclock and replace with comfort receiver for the wave. You will get weather compensation and control through using WiFi with wave
  18. Crofton Gas

    Smart Thermostat Help

    You'd need to get a gas safe engineer to take a supply from the boiler using 4core cable, doesn't need a separate supply
  19. Crofton Gas

    Smart Thermostat Help

    With nest you get a heatlink, you will need to fit near boiler then run 240v supply to heatlink, then a switched live from nest heatlink into boiler RT connection.
  20. Crofton Gas

    Smart Thermostat Help

    You would need to remove or disconnect the existing timeclock, then you can connect Nest to boiler Regards