  1. P

    Baxi Brazilia Fitting

    If questions are being asked like this then you are not a rgi or having a rgi do the work,they would know better ???
  2. P

    grand cherokee 3.1td

    Hi i am having trouble to start my jeep.have changed the glow plugs but still struggles to start from cold.Once started it is fine.Any help would be great thanks pete
  3. P

    Chaffeoteux Brittony SE combi

    hi i work for the contactor that covers the gas contract in barking and dagenham and we have been told that we can glue together the 2 halfs and mts have supplied a large jubilee clip to hold them together .believe me it does not look good,but manufactuer has sent it in writing that this is ok
  4. P

    boiler change

    Thanks dave for the all the help cheers pete
  5. P

    boiler change

    Thanks dave great help.The vent and cold feed can be connected to the flow before pump ,is there a certain way to pipe it.Sorry for any stupid questions peter
  6. P

    My Vaillant Turbomax VUW 242 boiler problem with hot water

    this sounds that the plate to plate exchanger is blocked and has tripped in the over heat stat.look in to boiler and on the left hand side you will see a rubber covered switch,make sure power is off and press switch.turn boiler back on,if it keeps tripping you have a blocked plate to plate peter
  7. P

    boiler change

    thanks for the replies.i think i will fit a valliant 400 series.On the wiring i will keep the y plan but will the pump only be wired direct to the boiler or in to junction center?Will the switch live be the orange and does this goto connector 4 on the boiler,i can see why i stick to combis alot...
  8. P

    boiler change

    customer wants to change neataheat electronic for a new boiler.I would like some advice please,would it be better to pressurise the system.Also should i fit a system boiler (VALLIANT).Am i right in thinking i would need a pump over run as the exsisting boiler does not have one.Could someone...
  9. P

    main water heater flue

    sorry its a balanced flue peter
  10. P

    main water heater flue

    hi just a quick question .Does any one know the size of hole requied for flue for main water heater.heater being delivered tomorrow pm but want to make hole in the morning thanks peter
  11. P

    Britony Combi se

    pcb common fault on these boilers,fitted loads last year
  12. P

    potterton combi 80 pressure problem

    if i can remember these have a braided hose going to the exp vessel these get blocked and cause this .i know this is true for the se but can not remeber if it the same with this unit pete
  13. P

    Chaff boiler clicks on and off

    hi i f i can remember these boilers have two flow switches that get stuck they work on a plunger.would not hurt to drain the boiler and clean them.also check to see if continuty is ok with multi meter pete
  14. P

    chipped acrylic bath

    hi does any one know of a company that can repair a small chip ,3mm sq ,in a acrylic white bath.i am based in romford essex.thanks for any advice on this cheers peter
  15. P

    potterton performa 24

    A big thanks to dave and superduper ,took the wire mesh filter out and bingo good circulation cheers guy i owe you one pete :D e
  16. P

    potterton performa 24

    Hi super looked at that cap and did not think any thing was in there.You live and learn thanks alot pete
  17. P

    potterton performa 24

    Hi dave thanks for the reply,have taken both valve off and the are open and checked to see if any mesh filters in the valves like the britony 80 but nothing.do you know where to get any manuals on these boilers thanks pete
  18. P

    potterton performa 24

    Hi just been to this boiler and have not had any dealings with them before so any help would be great.The hot water runs fine and gets nice and hot but on heating the boiler reaches temp very quickly and then starts to kettle.The flow pipe gets warm but no circulation.When i arrived on site the...