  1. A

    Connection Cost

    The new tails will run from a fused isolator, as the overall length will be over 3m. I have not installed anything yet, just deciding what i need. Can these tails be run in between the floor void?
  2. A

    Connection Cost

    Does anyone know the approx cost i should expect for the DNO to send someone out to connect a new set of tails from a new consumer unit and re seal the meter? Planning and costing our consumer unit move and just want to make sure everything is done above board. Already notified the LABC. Adam
  3. A

    Outside Light Switching

    Many thanks for your help.
  4. A

    Outside Light Switching

    Hi, Does anyone know if it is possible to get a standalone PIR sensor that can be wired as two way switching with another to switch a number of outside lights on from either sides of the house? A link would be appricated, tried screwfix but the wiring diagrams dont seam to have the correct...
  5. A

    Meter Tails Query

    oh and currently we have a three phase supply coming into the house, I was thinking of getting the DNO to come and change to SP, does anyone know what approx cost would this be? If they are changing the supply, i could provide the switchfuse for them to connect into, which would leave a...
  6. A

    Meter Tails Query

    Hi thanks for the replies. I am intending to do this work as one of my assessments to join NICEIC, I am in the process of notifying the work via LABC, i will be testing and providing a BS7671 certificate. I have my own test gear, which is just out of calibration but will be calibrated...
  7. A

    Meter Tails Query

    Hi, If i move a consumer unit and the new tails will be about =7m - 8m long do i need an 100A switchfuse unit or do i just need a 100A isolator after the meter before the long run? Cheers, Adam
  8. A

    BS7671 2008 (17th edition)

    Ive pre-ordered mine from NICEIC the other day. When should they arrive?
  9. A

    Power off lighting circuit

    :oops: sorry read the question wrong! I read it as just turning off at the switch (had a busy day) Ignore my comments!!
  10. A

    Power off lighting circuit

    DO shut the power off at the mains. If someone has wired the switch incorrectly then the fitting could still be live, also power will also be present in the ceiling rose even with the light switch turned off.
  11. A

    Consumer Unit Change - NICEIC Assessment

    Hi, Iam wishing to change the consumer unit(s) at home to a more modern setup. I will be using this job as one of my NICEIC assessment jobs for the domestic installer status. Iam currently in the 2nd year of the level2 2330. Firstly how do i go about legally doing the work, do i still have...
  12. A

    Using red & black twin & earth cable

    Just out of interest if you sheathed both conductors with blue and brown sheathing prior to terminating, would this conform to current regs?
  13. A

    13 AMP plug/socket

    A 13A 3pin plug will fit in any 13A socket outlet.
  14. A

    Downlights

    Yes i realise they may need to be moved slighty to one side to clear the joist. The room is a living room and above is a bedroom. I was just worried about the fact that the void is only small and full of insulation. I have seen normal downlights and fire rated ones. Just not sure which...
  15. A

    Downlights

    Hi, I wish to change some light fittings to downlights, the downlights will go in the same position as the old lights so i just need to cut the holes in the ceiling. The concern i have is the room is a downstairs room so it is quite a small cavity (around 6inch at a guess) and it is full...
  16. A

    burying Cat5 and speaker cables into the floor?

    I would run conduit or trunking first, it will save lots of problems later if you need to run a new wire. A new wire or a replacement can then simply be pulled through - in theory! Adam
  17. A

    Secure's Pic II

    Yeah, i realised after i had posted it was a bit of a silly comment! :-S
  18. A

    Basic Lighting / Diagrams

    Hi, You should be able to find things like that in the Wiki, http://www.diynot.com/wiki/electrics Adam
  19. A

    Secure's Pic II

    The sticker that says two versions of BS7671 colours??? I can only see old colours.
  20. A

    16A Industrial Socket Wiring

    I have a blue BS4343 socket that is used to plug in a folk lift charger. I wish to move this socket 2 metres along the wall using a length of SWA cable, Will i need 2.5 or 4mm cable? Also the socket is fed from a 32A breaker, is this the correct rating? The socket is rated at 16A so seams...