  1. Spark123

    Broadband connection problem - only works via test socket

    There has to be at least one more slave socket (probably the downstairs one) as there are two cables in the upstairs socket. Is there a connection somewhere as it leaves the main master socket orange + orange white and arrives at the upstairs socket blue + blue white. Or has someone been...
  2. Spark123

    Spur off of ringmain - whys it allowed!?

    25mm² ought to do it!
  3. Spark123

    earth impedance

    Reactance, both capacitive and inductive.
  4. Spark123

    TT Earthing problem?

    To test the resistance of a rod to ground you need a special type of meter with two more rods. It isn't really necessary when a Ze (or Ra) test can be carried out with an earth fault loop impedance tester. A multimeter is neither of these.
  5. Spark123

    OK...

    As it is only for milliseconds the power dissipated by the resistor (old wylex RCDs are somewhere in the region of 1.8KΩ) is very low, it shouldn't get chance to warm up. It is only when it the RCD fails that the resistor gets toasty and bad things happen.
  6. Spark123

    Where has he gone?

    A bit of a blast from the past, most of those members are no longer active on the forum and some are no longer with us, RIP Alastair
  7. Spark123

    REFERENCE - Useful manufacturer/product INFO

    Hager have issued a recall for some of their 10KA MCBs, See here for details: http://www.hager.co.uk/news-exhibitions-case-studies/news/all-news/news-archive/2016/mcb-issue/recall-of-hager-10ka-miniature-circuit-breaker-mcb-installer-communication/67566.htm?Suchbegriffe=recall#group
  8. Spark123

    3 phase conundrum

    Wet contact
  9. Spark123

    3 phase conundrum

    I'm not 100% sure with this but likelihood is the meter has a relay in it (with dry contacts*) for the off peak switching so when the off peak is active the relay is closed thus completing the circuit. The link to the neutral block will complete the circuit. The advantage being with dry relay...
  10. Spark123

    Lights off a Fire Alarm

    I don't see why not, if it wasn't OK then they wouldn't interconnect off the backup batteries when mains fails.
  11. Spark123

    3 phase conundrum

    Yes, it is a contactor for the off peak supply. The time switching will be done by the meter (switching the neutral wire on the left).
  12. Spark123

    Supply to a 63A RCB

    Table 4D5 is for normal twin and earth. Also if you are in a workshop using power tools it isn't a good idea to have lights on the same 30mA RCD (assuming that's what your 6A MCBs are for), if the RCD trips you may end up in darkness. What type of lights are you looking to use? Is this on the...
  13. Spark123

    Lights off a Fire Alarm

    I'd say it will kill them completely, iirc the interconnect is only a few volts DC wrt the neutral conductor.
  14. Spark123

    3 phase conundrum

    Possibly a time switch?
  15. Spark123

    Sparkies On Holiday

    New York?
  16. Spark123

    LED bulb flashes when off - but only when one of the 2-way switches is used

    Can you provide photos? I always wondered if arranging the conductors so the earth wire in the 3c+e is between the sw live (to the lamp) and other two conductors will make any odds.
  17. Spark123

    LED bulb flashes when off - but only when one of the 2-way switches is used

    I don't know of any off the shelf two way switches with a neon. I know you can get grid systems or an additional back plate with neon.
  18. Spark123

    LED bulb flashes when off - but only when one of the 2-way switches is used

    Can you upload some photo's of what you have including the wiring?
  19. Spark123

    Tripping Light Circuit

    I'm pretty sure I have seen some charts (Merlin Gerin / Schneider) which do allow full discrimination of certain MCBs but iirc I think it depends on fault current.
  20. Spark123

    Tripping Light Circuit

    Asbestos seal and probably flash pads?