Search results

  1. G

    glowworm micron 50ff start stop prob.querie

    The new pcb does do this it is a pre purge function which clears any gas that may be in the boiler prior to ignition.Ihave fitted many which do this
  2. G

    Glowworm 30cxi condensate leak

    No it is behind the heat exchanger it is called a flue adaptor and has a design change so the complete part will need to be changed not just the seal.The burner seal has changed as well and should be changed at the same time.The adaptor should be free as it is a design fault along with the left...
  3. G

    Special offer Hi-eff cond boiler + 7 rads fitted

    24 kw combi forget it, unless you only shower.
  4. G

    10 year guarantee

    Most if not all guarantees that are extended are costed into the appliance when you purchase them. Vaillant are doing a 3 year one but the price of the appliance will rise pro rata according to my local rep. Its a numbers game with the manufacturers,they are there to make profits you dont get...
  5. G

    Glowworm 30cxi and dropping pressure (Parts replaced)

    Isolate the boiler by turning the flow and return valves off ,turn the heating off as well.If the pressure drops then you have a leak boiler side,check the prv and the condesate pipes.If the dhw heat exchanger is cracked then the pressure of the mains will push the system pressure up not down.If...
  6. G

    Glowworm xtrafast 96 overheating problem

    F14 on this appliance usually means blocked or partially blocked secondary heat exchanger
  7. G

    Vaillant ecotec 630 Plus

    Well if they have replaced the sensor and pump ,and have still not cured the fault then i presume this would warrant a kit being used. The engineers should be aware of this remedy as it has been used to cure this fault on several occassions in my area.
  8. G

    Vaillant ecotec 630 Plus

    Above the pipe should read above the pump.
  9. G

    Vaillant ecotec 630 Plus

    There is a f75 kit which replaces the return pipe and has the sensor above the pipe.Vaillant have been using these where pump and sensor replacement have failed
  10. G

    Leak on Glowworm Compact 75

    Diaphram S801191 Diaphram cover S801201 Switch S801189 All available from H.R.P.C
  11. G

    valiant turbomax

    Which model
  12. G

    Gloworm Compact 80 lock out

    The compact P has a pilot the E is electronic ignition
  13. G

    Water temp on a compact 100p

    you can by adjusting the potentiometer on the pcb
  14. G

    Glow worm boiler leaking

    Could be the dhw tank leaking, boiler off the wall for repair if it is. Apart from that the boiler is easy to work on no more trouble than the major brands. Probably covered on glowworms fixed price parts and labour .
  15. G

    Vibrating humming glowworm 18hxi

    Still under warranty call glowworm
  16. G

    Glowworm 24/30ci

    The turbine sticks and frees itself they have had two upgrades to my knowledge. The first is identical sensor except the turbine is black.They then brought out a black sensor completely different shape same p/no though
  17. G

    Saunier Duval Xeon 60FF boiler won't run. Fan Hunting?

    Just look and see if the pilot is alight if it is only the neons 1 and 2 will light.If not have you put the link in terminal 9 and S/L ON THE PCB.Also recheck the wiring on the new pcb and the polarity or the wiring harness to the fan
  18. G

    Saunier Duval Xeon 60FF boiler won't run. Fan Hunting?

    Yes if the pilot stays on after a demand has finished, the boiler will not relight the burner.But if you cut the power or gas and then reinstate it the boiler will light. its caused by the gas valve not extinguishing the pilot so the next demand it will not light burner because it thinks it is...
  19. G

    Saunier Duval Xeon 60FF boiler won't run. Fan Hunting?

    Check if pilot is on permant if it is cut power boiler will light turn down stat boiler will not light because pilot stays on if this is the case new gas valve will solve prob
  20. G

    Glow worm Swiftflow losing pressure fast

    You could isolate the flow and return on the boiler if no pressure loss then a leak is system side.Warning though if you so much as look at those valves they tend to start leaking