  1. G

    Do megaflows etc really work OK on less than 20litres min ?

    Very often when these are installed, the difference between them and the previous vented system that they have replaced is significant enough for the end user to be impressed and happy with them, the people who will not necessarily be as happy are those that have done lots of research on them...
  2. G

    DePressurising a Worcester Highflow 400

    Might be worth getting the pressure relief valve inspected, it should have opened at around the 3bar mark. To release the excess pressure, open a draincock, or you could do it from a radiator bleed valve, but this could take some time. Relieve the excess pressure before firing up the boiler.
  3. G

    Vokera Compact Boiler

    Overheating? Faulty thermistor? When it is firing, are the radiators heaing up?
  4. G

    Problems with boiler - Vokera Maxin 28e

    To begin with, test the Exp Vessel still has charge. See FAQ's
  5. G

    Sterling Burner lockout

    Grant do useful course, good coverage of the Riello burners
  6. G

    flueless gas fires

    I often wonder if it is explained fully to end users the conditions of using these flueless fires, regular servicing essential, limited hours daily usage as a seconary heat source only etc
  7. G

    one rad not geting hot

    If either valve is not open, then there will be no flow through the rad.
  8. G

    Vokera Linea Boiler

    Put bottle / container over pipe as suggested, leave boiler running and check later.
  9. G

    Strange One

    Is the cold water working at the same outlets?
  10. G

    Vaillant 937 Heat Exchanger

    But do not use the softened water for the heating side of the boiler.
  11. G

    Vokera Linea Boiler

    Is the pressure relief pipe dripping, put a bottle or something over it, to see if it collects anything. Quite often, after the PRV opens, it does not reseat properly. Let us know if it is dripping.
  12. G

    Outlet Pipe from Worcester Greenstar Ri Boiler Frozen

    The boiler manufacturers do not provide the condensate pipe, only a connection point on the boiler itself and guidelines on how to install it which are based on a british standard which advises internal runs where possible, maximum lengths and lagging / upsizing the pipe if run externally.
  13. G

    Vaillant Boiler - problem with boiler

    Was the working pressure correct at the meter?
  14. G

    Vaillant 242 E Combi Expansion Vessel

    If water comes out of the schraeder valve then the EV has failed. Fitting an external EV is common practice where replacing the internal EV would require removing boiler from wall.
  15. G

    BAXI combi doesn't switch off

    Is your hot water working OK?
  16. G

    Burst Pipes headscratcher

    turn off stopcock in street, if you still have water on the kitchen cold supply then it must be fed from loft tank as Burnerman has said
  17. G

    Condensate Pipe

    Is there power to the boiler?
  18. G

    oil pump pressure settings ?

    Seeing as you are on a tiger loop, did you set the bypass screw?
  19. G

    Immersion Heater faulty - testing..?

    Element resistance should be approx 19.2ohms. (assuming 3kW element) Just use the fibre washer